Dryers

Electric and gas: no heat, long dry times, belts, rollers and venting.

17 field manuals · 112 error codes · 33 diagnostic guides · 8 brands

Field service manuals

Field manual · Dryer

Speed Queen dryer (DC5 / DR / DF series, gas and electric): field service manual

Speed Queen residential dryers built by Alliance Laundry: DC5 (classic mechanical controls), DR3/DR5/DR7 and DF7, about 7.0 cu ft, gas and electric versions.

6 components4 common failuresSpeed Queen

Field manual · Dryer

Whirlpool / Maytag / Kenmore 29-inch dryer (electric & gas): field service manual

Whirlpool-built 29-inch full-size dryers: the older mechanical-timer / basic-electronic platform and the newer electronic-console platform with F#E# codes. Gas and electric versions. Commercial-grade residential and Duet-era front-load companions are mentioned only where noted.

15 components6 common failuresWhirlpool, Maytag, Kenmore, KitchenAid, Amana, Roper

Field manual · Dryer

Samsung DV dryer (electric & gas): field service manual

Samsung DV-series 27-inch front-load-companion dryers with digital display (DVE electric / DVG gas), including models with vent-blockage sensing.

11 components5 common failuresSamsung

Field manual · Dryer

LG dryer (electric, gas, heat-pump): field service manual

LG 27-inch front-load-companion dryers with digital display (electric, gas, steam models); brief notes on LG ventless heat-pump models.

8 components5 common failuresLG

Field manual · Dryer

GE dryer (electric & gas): field service manual

GE and Hotpoint 27-inch dryers, mechanical-timer and electronic models (E-code models).

9 components4 common failuresGE, Hotpoint

Field manual · Dryer

Frigidaire / Electrolux dryer (electric & gas): field service manual

Frigidaire and Electrolux 27-inch dryers, including electronic models that show E-codes (E64, E66, E67, E68). Some Kenmore models are built on this platform.

9 components3 common failuresFrigidaire, Electrolux, Kenmore

Field manual · Dryer

Dryer venting & installation: field manual

Residential vented dryers (electric and gas), all brands. Exhaust duct rules, cord types and gas-install boundaries.

5 components3 common failuresAll

Field manual · Dryer

Whirlpool WED4815E / WED4850H / WED4950H-series electric dryer: quick sheet

Whirlpool 29-inch, 7.0 cu ft electric dryers WED4815EW, WED4850HW and WED4950HW (Canadian versions carry a Y prefix, e.g. YWED4815EW / YWED4850HW), plus engineering revisions. Gas twins use WGD. Years not confirmed by our sources (E, then H introduction letters); WED4815EW listed as no longer available.

9 components5 common failuresWhirlpool

Field manual · Dryer

Maytag MEDC465H-series electric dryer: quick sheet

Maytag MEDC465HW, 29-inch 7.0 cu ft electric dryer sold with the MVWC465H washer (gas twin MGDC465H), plus engineering revisions. Years not confirmed by our sources (H = introduction letter); listed as no longer available.

9 components5 common failuresMaytag

Field manual · Dryer

Maytag MED6230H-series electric dryer: quick sheet

Maytag MED6230HW, 27-inch 7.4 cu ft smart electric dryer with Extra Power and Wi-Fi, pair for the MVW6230H washer (Canadian version YMED6230HW; gas twin MGD6230H), plus engineering revisions. Years not confirmed by our sources (H = introduction letter); listed as discontinued.

9 components6 common failuresMaytag

Field manual · Dryer

Samsung DVE45R6100-series electric dryer: quick sheet

DVE45R6100W, DVE45R6100P, DVE45R6100V and DVE45R6100C electric dryers (7.5 cu ft, Steam Sanitize+), the match for the WF45R6100 washer, about 2019-2022 (Samsung spec sheets). Gas siblings are DVG45R6100*.

8 components4 common failuresSamsung

Field manual · Dryer

Samsung DVE45T6000-series electric dryer: quick sheet

DVE45T6000W (white) and DVE45T6000V (black stainless) 7.5 cu ft electric dryers with Sensor Dry, the match for WF45T6000, about 2020 onward (Samsung spec sheets revised 2023). Gas siblings are DVG45T6000*.

7 components4 common failuresSamsung

Field manual · Dryer

LG DLE3400W-series electric dryer: quick sheet

DLE3400W 7.4 cu ft electric dryer (gas twin DLG3401W), the match for WM3400CW; LG spec and builder sheets dated 2022 list it (approximate years 2018 onward).

7 components5 common failuresLG

Field manual · Dryer

LG DLEX4000-series electric dryer: quick sheet

DLEX4000W 7.4 cu ft electric dryers, gas twins DLGX4001*, match for WM4000H*A; LG builder spec sheets dated 2024 and 2025 (approximate years 2019 onward).

8 components6 common failuresLG

Field manual · Dryer

GE GTD42 / GTD65-series electric dryer: quick sheet

GE 27-inch electric dryers GTD42EASJ** (7.2 cu ft) and GTD65EBSJ** (7.4 cu ft, Sensor Dry), with the related GTD45EASJ** in the same generation. Late 2010s to early 2020s; GE marks both as no longer manufactured. Gas twins (GTD..G..) share the cabinet but the gas side is refer-out only.

8 components3 common failuresGE

Field manual · Dryer

Electrolux EFME627-series electric dryer: quick sheet

Electrolux EFME627UTT (Titanium) 8.0 cu ft front-load electric dryer with steam, the match to the EFLS627UTT washer; the gas twin is EFMG627UTT (gas side refer-out only). Sold roughly 2020 onward; listed as discontinued by retailers.

7 components4 common failuresElectrolux

Field manual · Dryer

Frigidaire FFRE4120-series electric dryer: quick sheet

Frigidaire FFRE4120SW 27-inch, 6.7 cu ft electric dryer, the match to the FFTW4120SW washer, sold roughly 2021 onward; common in rentals and new builds.

7 components3 common failuresFrigidaire

Diagnostic guides

Component test · Dryer

How to test a dryer thermal fuse

A thermal fuse is a one-time safety link that opens permanently when the exhaust gets too hot. It is a simple continuity test, but a blown fuse is a symptom: the real cause is almost always a restricted vent or a failed cycling thermostat.

5 steps ~20 mineasy

Component test · Dryer

How to test a high-limit thermostat (dryer and similar heaters)

A high-limit is a normally-closed bimetal switch that opens if the heater area overheats and closes again when it cools. A room-temperature continuity test catches the common "stuck open" failure, but it cannot prove the opening temperature is right.

5 steps ~20 mineasy

Component test · Dryer

How to test a dryer cycling (operating) thermostat

The cycling thermostat switches the heat on and off to hold the exhaust temperature. It should be closed when cold and open when hot. A stuck-closed unit overheats the dryer; a stuck-open unit gives no heat.

6 steps ~20 mineasy

Component test · Dryer

How to test a dryer heating element

An electric dryer element is a resistance coil on 240 V. Test it across the terminals and to ground. Most read in the low teens of ohms; use R = V²/W from the element rating to check yours.

6 steps ~40 minmoderate

Component test · Dryer

How to test a dryer drive motor and its centrifugal switch

Dryer motors have a centrifugal switch that drops out the start winding once the motor is up to speed and, on most models, also closes the heater circuit. Test the windings at the motor and the switch contacts in both positions.

6 steps ~45 minmoderate

Component test · Dryer

How to test gas dryer valve coils (electrical test only)

The gas valve has solenoid coils that open when the igniter is hot. You may test the coils with a meter at their terminals with power off. Gas line, valve body and burner work is blocked: refer to a licensed gas technician.

5 steps ~30 minmoderate

Guide · Dryer

Electric dryer runs but no heat

Most electric no-heat calls come down to supply voltage (one breaker leg), a blown thermal fuse from a restricted vent, a tripped high-limit, or an open element. Always fix the airflow cause, or the new fuse will blow again.

7 steps ~60 minmoderate

Guide · Dryer

Gas dryer runs but no heat (electrical checks only)

On a gas dryer the electrical side of the burner can be diagnosed safely with gas and power off: thermal fuse, high-limit, cycling thermostat, igniter, flame (radiant) sensor and gas valve coils. Gas supply, gas lines, the valve body and gas pressure are off-limits: refer to a licensed gas technician.

6 steps ~60 minadvanced

Guide · Dryer

Dryer takes too long / vent restriction

Slow drying with heat present is almost always airflow. Check the whole exhaust path and its length before suspecting parts, then look at the moisture sensor and heat cycling.

4 steps ~45 mineasy

Guide · Dryer

Dryer won't start

Separate 'dead' (no display) from 'display OK but no start'. Common causes are supply, door switch, thermal fuse (on designs where it is in the motor/control circuit), start switch, belt switch and the drive motor.

5 steps ~45 minmoderate

Guide · Dryer

Drum not turning (motor runs or hums)

Hand-turn the drum first: free-spinning means a broken belt; heavy or locked means rollers, idler, bearing or a jammed blower. Replace the idler with the belt when it is worn.

4 steps ~60 minmoderate

Guide · Dryer

Dryer squealing, thumping or grinding

Noise is mechanical wear in the drive and drum support: idler pulley, drum rollers, glides/felt seals, blower debris, or a belt with a flat spot. Identify by sound and hand-spin.

4 steps ~60 minmoderate

Guide · Dryer

Dryer stops early / clothes still damp

An auto cycle that ends early is usually the moisture sensor reading dry (residue, unlevel, small load). A dryer that stops mid-cycle and restarts later suggests motor overheating or a heat-related shutoff.

3 steps ~30 mineasy

Guide · Dryer

Dryer overheating / cabinet too hot

Overheating is a fire risk. Restriction is the usual cause; after that, a cycling thermostat stuck closed, an element grounded to the housing, or a heater relay stuck on can keep heat on.

4 steps ~60 minmoderate

Guide · Dryer

Moisture sensor problems (auto dry wrong)

Moisture sensing uses two metal bars that wet clothes bridge. Residue, unlevel installs, small loads and loose wiring cause most complaints.

3 steps ~20 mineasy

Install · Dryer

Dryer vent installation: materials, length, elbows and termination

Use 4 in rigid or semi-rigid metal duct with a smooth interior, keep the run within the code or manufacturer limit (the model code limit is 35 ft, reduced for each elbow, unless the dryer maker allows longer), and terminate outside with a backdraft damper and no screen. Never vent into an attic, crawl space or wall cavity.

5 steps ~120 minmoderate

Install · Dryer

Electric dryer cord change (3-wire to 4-wire or reverse)

Match the cord to the receptacle. With a 3-wire cord the neutral-to-cabinet ground strap (or green screw link) stays in place. With a 4-wire cord the strap is removed, the green wire goes to the cabinet ground screw and the white to the center neutral terminal only.

5 steps ~30 mineasy

Install · Dryer

Gas dryer connection (BLOCKED: refer to a licensed gas installer)

Connecting, disconnecting or leak-testing a gas line is licensed gas work in most US jurisdictions. A handyman may prepare the space, the 120 V outlet and the vent, then the gas connection and leak test go to a licensed gas installer or plumber.

4 steps ~30 minadvanced

Guide · Dryer

Speed Queen dryer runs but does not heat (electric)

Most cases are a blown thermal fuse and/or failed high-limit caused by a restricted vent. Clear the vent before replacing parts, then test the fuse, high-limit and element.

4 steps ~60 minmoderate

Guide · Dryer

Dryer trips the breaker

Tripping when heat starts usually points to a heater element shorted to its housing; tripping at start points to the motor or wiring; tripping at random may be a weak breaker or loose connection. Rule out the terminal block and cord first.

4 steps ~45 minmoderate

Guide · Dryer

Burnt power cord or terminal block

Loose cord screws heat up under the dryer's high current and burn the terminal block. The fix is a new cord and block installed exactly per the install instructions for 3-wire or 4-wire.

3 steps ~30 minmoderate

Guide · Dryer

Heat-pump (ventless) dryer drying poorly

Heat-pump dryers are slower than vented dryers by design. Real faults are usually clogged lint or condenser filters, a blocked drain path, or a cold room. The refrigerant circuit is sealed: diagnosis only.

4 steps ~30 mineasy

Guide · Dryer

Dryer door won't stay closed or dryer stops when bumped

A worn strike or catch, a cracked plastic strike, or a weak door switch actuator makes the control see the door open. Inspect mechanicals before replacing the switch.

3 steps ~20 mineasy

Guide · Dryer

Clothes come out wrinkled

Usually overload, over-drying, or clothes left in the drum. Check moisture sensing and cool-down.

4 steps ~20 mineasy

Guide · Dryer

Dryer drum light not working

Bulb or LED module, door switch, or drum-light circuit. Some GE Profile models show a code for the drum light circuit.

3 steps ~20 mineasy

Guide · Dryer

Dryer steam features not working

Steam dryers use a feeder or a hose supply. Check water, inlet filter and valve, then the steam generator thermistor.

4 steps ~40 minmoderate

Guide · Dryer

Water or condensation inside the dryer

Usually a long, cold or sagging vent where moisture condenses and runs back, or a blocked vent.

4 steps ~45 minmoderate

Guide · Dryer

Lint filter not detected or lint filter codes

Several dryers sense the lint filter. Seat the filter fully, clean it, then check the sensing switch.

3 steps ~15 mineasy

Guide · Dryer

Dryer will not connect to the app (Wi-Fi)

Most cases are 2.4 GHz network, registration or router issues; a few are module faults.

4 steps ~20 mineasy

Guide · Dryer

Dryer smells like gas (BLOCKED: refer)

Safety only. Do not diagnose the gas train. Leave, avoid ignition sources, and call the gas utility or a licensed gas technician.

3 steps ~5 minadvanced

Guide · Dryer

Clothes too hot / dryer running hot

Most often restricted airflow; also a failed cycling thermostat, thermistor or stuck heater relay.

4 steps ~45 minmoderate

Guide · Dryer

Ventless dryer water tank and condensate codes

Condenser and heat-pump dryers collect water in a tank or pump it out. Empty tank, clean float, clear hose.

4 steps ~20 mineasy

Guide · Dryer

Reading airflow / vent-test codes

Airflow codes rate vent restriction. Clean filter, then whole duct, then hood.

3 steps ~45 minmoderate

Bosch · 11 codes

Frigidaire / Electrolux · 17 codes

Frigidaire / Electrolux · Dryer

E4A

Outlet (exhaust) thermistor

Exhaust thermistor reads abnormal; dryer falls back to timed drying.

Single source

Frigidaire / Electrolux · Dryer

E5A

Inlet thermistor

Inlet thermistor failed.

Single source

Frigidaire / Electrolux · Dryer

E51

Motor relay fault

Motor relay stuck or open; control cannot switch the motor correctly.

Cross-checked

Frigidaire / Electrolux · Dryer

E52 / E53 / E54

Motor fault / low motor voltage / no motor feedback

E52 motor stopped or not starting; E53 low voltage read from motor; E54 no motor feedback.

Single source

Frigidaire / Electrolux · Dryer

E61

Heater relay fault

Heater relay circuit faulty: cannot power the element or stuck closed.

Cross-checked High-voltage / caution

Frigidaire / Electrolux · Dryer

E64

Heater circuit open

The control detects the heater circuit as open: the drum turns but no heat is produced.

Cross-checked High-voltage / caution

Frigidaire / Electrolux · Dryer

E65

High-limit tripping repeatedly

High-limit thermostat has opened too often: recurring overheating.

Single source High-voltage / caution

Frigidaire / Electrolux · Dryer

E66

Thermal limiter open (per one source)

One service-code list says the thermal limiter circuit is open; another source ties E66 to the heater relay.

Single source High-voltage / caution

Frigidaire / Electrolux · Dryer

E67

Heater sensing fault

Sources disagree: one lists a heater-sensing failure on the main board, another a tripped inlet thermal limiter or heater wiring fault.

Single source High-voltage / caution

Frigidaire / Electrolux · Dryer

E68

Stuck key

A control panel key reads as stuck.

Cross-checked

Frigidaire / Electrolux · Dryer

E71 / E72

Temperature probe fault

Temperature probe or sensor problem.

Single source

Frigidaire / Electrolux · Dryer

E91 / E92 (dryer)

UI to main board communication

Communication error between boards.

Single source

Frigidaire / Electrolux · Dryer

E93 (dryer)

Configuration error

Board configuration does not match the model.

Single source

Frigidaire / Electrolux · Dryer

E95 (dryer)

Supply voltage error

Abnormal line voltage.

Single source High-voltage / caution

Frigidaire / Electrolux · Dryer

EF0 (dryer)

Exhaust flow restriction

Restricted exhaust airflow; fire-safety warning.

Single source High-voltage / caution

Frigidaire / Electrolux · Dryer

EF1 / EF4

Check exhaust alarm / warning

Listed as exhaust alarm (EF1) and warning (EF4), pointing to vent restriction or a faulty high-limit thermostat.

Single source

Frigidaire / Electrolux · Dryer

EH0 (dryer)

Heater circuit fault

Abnormal heater circuit condition such as ground fault or overcurrent.

Single source High-voltage / caution

GE · 7 codes

LG · 23 codes

LG · Dryer

Add Water

Steam water supply

Steam feeder empty or not closed.

Cross-checked

LG · Dryer

AE (dryer)

Compressor restart failure

Compressor failed to restart.

Single source Licensed pro only

LG · Dryer

d75 / d80 / d90 / d95 (Flow Sense)

Exhaust restriction level

The exhaust duct is restricted by roughly the percentage shown. On gas models d80 can also show when gas supply is low.

Cross-checked

LG · Dryer

dE

Door not detected closed

The control sees the door as open.

Cross-checked

LG · Dryer

dHE

Temporary dry function error

Temporary drying fault.

Cross-checked

LG · Dryer

E05 / E5

Steam water supply problem

Water supply for steam cycles not reaching the unit.

Cross-checked

LG · Dryer

E13

Condensate drain

Drain hose kinked, crushed, clogged or sump water frozen.

Cross-checked

LG · Dryer

EE (dryer)

EEPROM error

Control memory abnormal.

Single source

LG · Dryer

F0 / Insert Filter

Lint filter not seated

Lint filter not fully inserted; dryer stops.

Cross-checked

LG · Dryer

gAS (may read as 9A5)

No gas supply detected

The gas dryer is not getting gas or not establishing flame.

Cross-checked Licensed pro only

LG · Dryer

HS

Humidity (moisture) sensor fault

The moisture sensor is not reading properly; the dryer may fall back to a long fixed run (about 2.5 hours per LG).

Cross-checked

LG · Dryer

LE

Motor locked / restricted

Listed in a service-code reference as the drum motor being bound or locked; not found on LG's consumer page.

Single source

LG · Dryer

LE1 / LE2

Motor restricted / low current

LE1 restricted motor; LE2 low current.

Single source

LG · Dryer

nE (dryer)

Control-to-Wi-Fi module link

Communication problem between the control panel and the Wi-Fi module (per LG and a repair site). One parts site lists a vibration-sensor error instead; confirm by model.

Cross-checked

LG · Dryer

nF (dryer)

Wi-Fi module problem

Wi-Fi module problem or product not registered.

Cross-checked

LG · Dryer

nP

No current at heater

The dryer runs but detects no current through the heater circuit, usually pointing to the home supply.

Cross-checked High-voltage / caution

LG · Dryer

OE (dryer)

Condensate drain error

Condensate pump/drain fault.

Single source

LG · Dryer

PF

Power failure

Power was interrupted, typically after an outage.

Cross-checked

LG · Dryer

PS

Power cord / supply wiring fault

Improper voltage at the power cord, often from a miswired terminal block (white and red swapped) or incorrect house supply.

Cross-checked High-voltage / caution

LG · Dryer

tE1

Thermistor fault

A problem was detected in the dryer's thermistor circuit.

Cross-checked

LG · Dryer

tE2

Thermistor fault (cold conditions)

Thermistor error usually tied to a cold duct, for example during steam cycles or with a cold/icy vent.

Cross-checked

LG · Dryer

tE3

Thermistor fault (high-temperature sensor)

Thermistor circuit problem; one service-code list describes it as the high-temperature thermistor reading open.

Cross-checked

LG · Dryer

tE4

Thermistor out of range (steam generator)

Thermistor reading out of range; parts list ties it to the steam generator thermistor.

Cross-checked

Miele · 12 codes

Samsung · 21 codes

Samsung · Dryer

3E / 3C

Drum motor fault

The control reports a drum motor problem (motor not turning the drum or its relay circuit); Samsung itself only says to restart and call service.

Cross-checked

Samsung · Dryer

5C / 5E (dryer)

Condensate drain / water tank

Drain pump or drain path problem, frozen drain hose, or full water tank.

Single source

Samsung · Dryer

9C1 / 9E / 9E1

Abnormal supply voltage

The control detected supply voltage outside its expected range.

Cross-checked High-voltage / caution

Samsung · Dryer

AC6 / AE6

Main to inverter board communication

Main and inverter boards are not communicating.

Single source

Samsung · Dryer

AE / AC

Board communication fault

Two internal boards (for example main board and display board) are not talking to each other.

Cross-checked

Samsung · Dryer

bE / bE2 / bC2

Stuck button

A control button reads as pressed for too long (typically 30 seconds or more).

Cross-checked

Samsung · Dryer

C1 / CL1

Laundry in drum during vent test

Vent test found laundry in the drum.

Cross-checked

Samsung · Dryer

C8 / C80 / C9 / C90 / Clg

Vent blockage warning

The dryer estimates the exhaust is restricted: C8/C80 about 80 percent, C9/C90 more than 90 percent; Clg means clogged after the vent test.

Cross-checked

Samsung · Dryer

CL (dryer)

Child Lock on

Control buttons disabled; on some models door locked.

Single source

Samsung · Dryer

Ct

Room temperature out of range

The dryer's surroundings are below freezing or above about 104 F.

Cross-checked

Samsung · Dryer

dF / dE / dC / d0 / 1dF

Door / door switch fault

The control is not getting a valid door-closed signal, or the door sensing circuit has an open connection.

Cross-checked

Samsung · Dryer

dn (dryer)

Firmware download

Firmware downloading; do not unplug. Service if it lasts over 24 h.

Cross-checked

Samsung · Dryer

dt / oD

Dry time / over-dry condition

Sources disagree: one describes the drying time exceeding its limit, another describes the moisture sensor calling the load dry too early.

Single source

Samsung · Dryer

FE / FC

Power frequency fault

The control sees an invalid supply frequency or an abnormal power condition.

Cross-checked High-voltage / caution

Samsung · Dryer

FIL + tEr

Clean heat exchanger

Heat exchanger needs cleaning (buzzer sounds).

Single source

Samsung · Dryer

HC2

Gas ignition error

Burner failed to ignite.

Cross-checked Licensed pro only

Samsung · Dryer

HE / hE / HC

Heating / overheat fault

The control saw an abnormal heating condition, usually exhaust temperature running too high, and in some cases heat not behaving as expected. On gas models a supply problem can also bring this up.

Cross-checked High-voltage / caution

Samsung · Dryer

NC / NC1

Lint filter problem

Lint filter assembly not detected or problem with it.

Single source

Samsung · Dryer

NC2

Heat exchanger cover problem

Internal heat exchanger cover not detected correctly.

Single source

Samsung · Dryer

tC5 / tE5

Compressor temperature sensor

Compressor temperature sensor problem.

Single source High-voltage / caution

Samsung · Dryer

tO / tS / tE / tC

Temperature sensor (thermistor) fault

The thermistor reading is outside its valid range. On many models tO points to an open sensor circuit and tS to a shorted one.

Cross-checked

Speed Queen · 2 codes

Whirlpool / Maytag / KitchenAid / Amana · 19 codes

Whirlpool / Maytag / KitchenAid / Amana · Dryer

AF / F4E3 / Check Vent

Restricted airflow

The lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns. The dryer keeps running; any key clears the message.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F01

Machine control fault

A fault inside the machine control electronics; one tech-sheet-based source ties it to the motor relay circuit on the control.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F1E1

Main control fault

The main control board has detected an internal failure (one repair reference ties it to a stuck motor relay on the board). Whirlpool only gives reset steps.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F2E1

Keypad / stuck key

The control sees a keypad problem, usually a stuck key.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F3E1

Exhaust thermistor open or shorted

The exhaust thermistor circuit reads open or shorted.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F3E2

Moisture sensor fault

The moisture sensor has not registered data for several consecutive loads (Whirlpool says five), or the sensor circuit is open/shorted.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F3E3

Inlet thermistor fault

The inlet (heater-side) thermistor circuit reads out of range.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F4E1

Heater or heater relay fault

The control suspects a problem with the heater or the heater relays.

Cross-checked High-voltage / caution

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F4E4

Low or no line voltage

Per Whirlpool, the control sees low or no voltage on the second 240 V leg, so the heater cannot run; the drum may still tumble with no heat.

Cross-checked High-voltage / caution

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F6E1

Communication error

The main control and the user interface are not communicating.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F7 E2 (heat-pump)

Dryer fan fault

Dryer fan problem.

Single source

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F7 E3 (heat-pump)

Compressor fault

Dryer compressor problem.

Single source Licensed pro only

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F9 E2 (heat-pump)

Water tank full

Condensate water tank is full.

Single source

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F22

Exhaust thermistor open

The exhaust (outlet) thermistor circuit is open.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F23

Exhaust thermistor shorted

The exhaust (outlet) thermistor circuit reads shorted.

Cross-checked

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F28

Meaning varies by platform

Sources disagree: one service manual reference ties it to the UI being unable to read its memory (EEPROM), others to the drive motor/relay or the moisture sensor. Check the tech sheet behind the console.

Single source

Whirlpool / Maytag / KitchenAid / Amana · Dryer

F31

L2 low line voltage

Low or missing line voltage on one leg; the heater will not come on.

Cross-checked High-voltage / caution

Whirlpool / Maytag / KitchenAid / Amana · Dryer

L2

Low or no line voltage

Supply voltage is too low for the heater; the dryer may tumble but not heat. Often only one 240 V leg is reaching the unit.

Cross-checked High-voltage / caution

Whirlpool / Maytag / KitchenAid / Amana · Dryer

PF

Power failure

Power was interrupted during a cycle. Informational.

Cross-checked

Official manufacturer support

We link to official documentation and never host it.