Dehumidifiers
Not collecting water, icing coils, pumps and error codes.
4 field manuals · 49 error codes · 11 diagnostic guides · 9 brands
Field service manuals
Diagnostic guides
Aprilaire · 8 codes
Aprilaire · Dehumidifier
E1
Internal humidity/temperature sensor failure
The user interface is not getting a good signal from its on-board RH/temperature sensor board.
Aprilaire · Dehumidifier
E2
High refrigeration pressure / temperature
The compressor discharge got too hot; the code clears by itself unless it repeats on several starts in a row.
Aprilaire · Dehumidifier
E3
Wall control (Model 76) communication lost
The unit is configured for a remote wall control and cannot talk to it.
Aprilaire · Dehumidifier
E4
Insufficient capacity
The coil (suction line) did not cool down enough after the compressor started, so the unit cannot reach its setpoint.
Aprilaire · Dehumidifier
E5 / E6
Thermistor failure (high temp E5 / low temp E6)
The high-temperature or low-temperature (frost) thermistor reads open or shorted.
Aprilaire · Dehumidifier
E7
Float switch open
The float switch input is open: water in the secondary pan, a faulty or wrong-type switch, or a missing jumper when no switch is used.
Aprilaire · Dehumidifier
E8
Inlet air out of range
Incoming air is too cold (below about 50 F), too hot, or too dry (dew point below about 40 F) for the compressor to run. It clears by itself.
Aprilaire · Dehumidifier
E9
Outdoor temperature sensor failure
The outdoor sensor signal is out of range; only shown when ventilation with temperature limits is enabled.
Danby · 5 codes
Danby · Dehumidifier
E2
Room temperature sensor fault
The ambient thermistor failed.
Danby · Dehumidifier
E3
Coil temperature sensor fault
The evaporator coil sensor failed.
Danby · Dehumidifier
E4
Humidity sensor fault
The relative-humidity sensor failed.
Danby · Dehumidifier
EC
Display/main board communication error
Display and main board are not talking. (Some generic sources use EC for refrigerant problems on other brands.)
Danby · Dehumidifier
P2
Defrost / coil protection (status)
The unit pauses to defrost or protect the coil.
Frigidaire · 5 codes
Frigidaire · Dehumidifier
AS / ES / F1 / F2 / L1 / F5
Temperature or humidity sensor fault
The control lost a valid reading from the room humidity sensor or a temperature (coil or room) sensor.
Frigidaire · Dehumidifier
E4 / C5
Electronic control failure
The control board detected an internal fault.
Frigidaire · Dehumidifier
EC / F0
Sealed system failure
The control decided the refrigeration circuit is not cooling the coil as it should, which Frigidaire treats as a sealed-system failure.
Frigidaire · Dehumidifier
H3 / E5
Compressor overload protection
The compressor protector tripped because the unit ran too hot or could not shed heat.
Frigidaire · Dehumidifier
PU
Pump-out failure
The pump did not empty the bucket within the time the control allows.
GE · 5 codes
GE · Dehumidifier
88
Waiting for setpoint (not a fault)
Shown at power-up until a humidity setting is chosen.
GE · Dehumidifier
E1
Humidity sensor error
The humidity sensor reading is faulty.
GE · Dehumidifier
E2
Temperature sensor error
A temperature sensor reading is faulty.
GE · Dehumidifier
P1 / E0 / E01
Pump not pumping in pump-out mode
The unit is set to pump out but the pump is not moving water.
GE · Dehumidifier
P2
Bucket full
The bucket is full and must be emptied.
Hisense · 4 codes
Hisense · Dehumidifier
E2
Control panel communication error
Display/keypad and main board are not communicating.
Hisense · Dehumidifier
E3
Room temperature sensor fault
Room sensor reads open or shorted.
Hisense · Dehumidifier
E4
Evaporator coil sensor fault
Coil sensor reads open or shorted.
Hisense · Dehumidifier
EC
Memory (EEPROM) error
The main board memory reports a fault.
Honeywell · 6 codes
Honeywell · Dehumidifier
E1 / E2
Temperature sensor fault
A temperature sensor input is faulty.
Honeywell · Dehumidifier
E3
Refrigeration protection / high room temperature
The unit stopped to protect the refrigeration system, typically because the room is too hot or the unit was recently moved or tipped.
Honeywell · Dehumidifier
E5
Pump or drainage fault
The pump or drain path is not clearing water.
Honeywell · Dehumidifier
EH
Humidity sensor fault
The humidity sensor reading is faulty.
Honeywell · Dehumidifier
P1
Water tank pulled out / not seated
The tank is out, misseated or full.
Honeywell · Dehumidifier
SA
Rest period (not a fault)
After about 24 hours of running the unit pauses for about an hour, then restarts by itself.
LG · 5 codes
LG · Dehumidifier
CH
Refrigerant leak detected
LG uses this code to report a refrigerant leak; there is no owner fix.
LG · Dehumidifier
CH 01 / CH 02 / CH 03
Electronic fault (humidistat or main board)
The control found a fault in the humidity sensing circuit or main board.
LG · Dehumidifier
CH 24
Pressure switch error
The refrigeration pressure protection tripped, usually from poor airflow.
LG · Dehumidifier
CH 67
Fan lock error
The control did not see the fan turning when commanded.
LG · Dehumidifier
CL
Child lock on (not a fault)
The control panel is locked; buttons do nothing until it is released.
Midea · 6 codes
Midea · Dehumidifier
AS
Humidity sensor error
The room humidity sensor reading is missing or out of range.
Midea · Dehumidifier
E3
Unit malfunction
Midea lists this as a general malfunction with no further detail.
Midea · Dehumidifier
Eb
Bucket removed or misplaced (pump models)
On pump models the control sees the bucket missing or out of position.
Midea · Dehumidifier
EC
Refrigerant leakage detection
The control concluded the coil is not getting cold, which it treats as a refrigerant loss.
Midea · Dehumidifier
ES
Evaporator tube temperature sensor error
The coil (evaporator tube) thermistor reading is missing or out of range; this sensor drives defrost control.
Midea · Dehumidifier
P2
Bucket full or not seated
The float switch reports a full or missing bucket; the compressor stops.
TCL · 5 codes
TCL · Dehumidifier
E1 / E2
Temperature sensor fault
A temperature sensor or the main board is reporting a fault.
TCL · Dehumidifier
E3
Refrigeration protection / suspected low charge
The unit sees poor coil temperature change and cycles off; low refrigerant is possible.
TCL · Dehumidifier
E5
Pump sensor fault
The pump or its sensor reports a problem.
TCL · Dehumidifier
EH
Humidity sensor fault
The humidity sensor signal is invalid.
TCL · Dehumidifier
P1
Bucket not in place
The bucket is missing or not seated on its switch.