Air Conditioners

Window, portable and mini-split: codes, capacitors, drainage and airflow.

12 field manuals · 124 error codes · 34 diagnostic guides · 13 brands

Field service manuals

Field manual · Air Conditioner

Window air conditioner (incl. U-shaped inverter): field service manual

Standard box-type window units with mechanical or electronic controls and U-shaped inverter window units (Midea U style and similar saddle designs). Series names only; confirm details on the model's tech sheet.

9 components8 common failuresFrigidaire, GE, LG, Midea

Field manual · Air Conditioner

Portable air conditioner (single and dual hose): field service manual

Floor-standing portable units with one or two window hoses, internal condensate tank or pump, and auto-evaporation in cooling mode.

6 components6 common failuresGE, LG, Frigidaire, Midea, Haier

Field manual · Air Conditioner

Ductless mini-split heat pump / AC: field service manual

Single- and multi-zone inverter ductless systems with wall-mount, ceiling cassette or slim-ducted indoor units. Code meanings are in the air-conditioner error code list; this manual covers concepts and safe electrical checks.

8 components6 common failuresMitsubishi Electric, Daikin, Fujitsu, LG, Pioneer, MrCool, Midea

Field manual · Air Conditioner

Central split AC: electrical diagnostics field manual

Residential split systems with a single-stage outdoor condensing unit, an indoor furnace or air handler and a conventional 24 V thermostat. Covers the control and line-voltage electrical side only.

9 components6 common failuresAll

Field manual · Air Conditioner

Split heat pump: electrical basics field manual (reversing valve coil & defrost board)

Residential single-stage split heat pumps with a time-temperature or demand defrost board and a conventional heat pump thermostat. Electrical side only; the refrigerant circuit is out of scope.

7 components5 common failuresAll

Field manual · Air Conditioner

MrCool DIY 4th Gen mini-split: quick sheet

MrCool DIY 4th Generation single-zone and multi-zone ductless heat pumps (R-410A) with pre-charged Quick Connect line sets. The 5th Gen (R-454B) replaced it; 5th Gen R-454B line sets are not compatible with 4th Gen units.

6 components4 common failuresMrCool

Field manual · Air Conditioner

Mitsubishi M-Series wall units MSZ-GL and MSZ-FS (Hyper-Heat): quick sheet

Mitsubishi Electric M-Series wall-mounted heads MSZ-GL (paired with MUZ-GL outdoor units) and MSZ-FS (paired with MUZ-FS / MUZ-FS…NAH Hyper-Heat). Sizes 6K-24K; suffixes NA-U1/U2. Single-zone or multi-zone capable.

6 components3 common failuresMitsubishi Electric

Field manual · Air Conditioner

Daikin 19 Series wall-mount mini-split (FTX/RX): quick sheet

Daikin 19 Series single-zone wall units sold in the US as FTX…NMVJU / RX…NMVJU (older, rated about 18-19 SEER) and FTX…BXVJU / RX…BXVJU (about 20 SEER2) in 9K-24K sizes. Newer Daikin Oterra (FTXF, R-32) is a different platform. Exact years not confirmed.

5 components2 common failuresDaikin

Field manual · Air Conditioner

Pioneer WYS ductless mini-split (Inverter++): quick sheet

Pioneer WYS-series wall-mount systems sold online (e.g. WYS012GMFI22RL = indoor WS012GMFI22HLE + outdoor YN012GMFI22RPE; earlier 21.4 SEER2 WYS012GMFI20RL). R-410A versions are being discontinued; check the label for refrigerant.

5 components2 common failuresPioneer

Field manual · Air Conditioner

Midea U-shaped inverter window AC (MAW…V1QWT / U1QWT): quick sheet

Midea U-shaped inverter window units: MAW08V1QWT, MAW10V1QWT, MAW12V1QWT and earlier MAW…U1QWT models. Years not confirmed; check the rating label.

6 components3 common failuresMidea

Field manual · Air Conditioner

LG Dual Inverter window AC (LW…IVSM): quick sheet

LG Dual Inverter Smart window units such as LW8022IVSM (8,000 BTU) and LW1022IVSM (10,000 BTU), 115 V, R-32 refrigerant, ThinQ Wi-Fi. Earlier LW…IVSM generations look similar; confirm refrigerant on the label.

5 components2 common failuresLG

Field manual · Air Conditioner

Frigidaire Gallery inverter window AC (FHWW / GHWQ): quick sheet

Frigidaire Gallery Inverter Quiet Temp window units: earlier FHWW…(e.g. FHWW124WD1, listed as discontinued) and current GHWQ…(e.g. GHWQ123WC1, GHWQ125WD1), 12,000 BTU class, Wi-Fi.

5 components2 common failuresFrigidaire

Diagnostic guides

Guide · Air Conditioner

PTAC not cooling (fan runs, air not cold)

Most PTAC no-cool calls are airflow (filter, coils), a wrong control setting or a failed compressor start component. Rule those out before suspecting the sealed system.

6 steps ~60 minmoderate

Guide · Air Conditioner

PTAC not heating (electric heat or heat pump)

PTACs heat with electric strip heat, a heat pump, or both. Heat pump models switch to strip heat in cold weather. Check settings, then the heater element and its limits, then the reversing valve.

5 steps ~60 minmoderate

Guide · Air Conditioner

PTAC error codes: how to read and clear them

Most PTAC brands store fault codes that can be shown with a button combination on the control (for example GE Zoneline uses a MODE + another key sequence on some models). Read the active code, fix the cause, then clear it.

4 steps ~20 mineasy

Guide · Air Conditioner

Mini-split indoor unit dripping water

Indoor head leaks are almost always drain related: clogged pan or line, poor line slope, a failed condensate pump, or the head not level. Ice on the coil from low airflow or low charge is the next suspect.

6 steps ~45 mineasy

Guide · Air Conditioner

Mini-split louvers (vanes) not moving

Vanes are driven by small stepper (swing) motors. Check the swing setting first, then the linkage for a broken clip, then the motor and its connector.

4 steps ~30 mineasy

Guide · Air Conditioner

Mini-split smells (musty, dirty-sock, burning)

Musty or dirty-sock smell is biological growth on the coil, blower wheel and drain pan. Burning or electrical smell is a different job: stop the unit and inspect electrical parts.

5 steps ~90 minmoderate

Guide · Air Conditioner

AC/heat pump outdoor fan not spinning

On conventional units the usual causes are a failed fan capacitor, a seized motor or a contactor problem. On inverter mini-splits the fan is driven by the board and usually posts a fan error code.

5 steps ~45 minmoderate

Guide · Air Conditioner

Window AC smells musty or moldy

Standing water in the base pan, slime on the coil and a dirty blower wheel cause most odors. Units tilted wrong or stored wet are frequent offenders.

5 steps ~60 minmoderate

Guide · Air Conditioner

Air conditioner tripping the breaker

Find out when it trips: instantly (short to ground), at compressor start (hard start, bad capacitor, weak breaker) or after running (overload, loose connection heating up). Never upsize a breaker beyond the nameplate maximum.

6 steps ~60 minadvanced

Guide · Air Conditioner

Portable AC: exhaust hose, poor cooling and hot hose

Portable ACs depend on the exhaust hose. Long, kinked or extended hoses and leaky window kits pull hot air back in. Single-hose units also create negative pressure that draws in outside air.

4 steps ~30 mineasy

Guide · Air Conditioner

Mini-split remote modes and settings explained

Many no-cool calls are remote settings: wrong mode, dry mode, auto with a wide band, sleep, eco or timers. Learn the mode icons and reset the remote before tearing into the system.

5 steps ~15 mineasy

Guide · Air Conditioner

Air conditioner running but not cooling enough

Most no-cool calls on room units are airflow, installation or sizing problems, not hardware. Measure the temperature drop across the unit first, then work through filter, coils, air leaks and heat load before suspecting the sealed system.

6 steps ~30 mineasy

Guide · Air Conditioner

Air conditioner blowing warm or room-temperature air

Warm air with a running fan means the compressor is not running or not pumping. Confirm the mode and setpoint, then check whether the compressor is actually starting before looking at capacitor, overload and contactor.

4 steps ~45 minmoderate

Guide · Air Conditioner

Air conditioner freezing up (ice on the coil)

Ice forms when the coil gets too cold, nearly always from low airflow or running in cool weather. Thaw first, then fix airflow. Repeated icing with good airflow suggests low charge, which is sealed-system work.

5 steps ~60 mineasy

Guide · Air Conditioner

Air conditioner dripping or leaking water indoors

Condensate is supposed to drain outdoors. Indoor leaks come from wrong tilt, blocked drain openings or lines, a frozen coil melting off, or a cracked pan / failed pump.

5 steps ~30 mineasy

Guide · Air Conditioner

Air conditioner short cycling (turns on and off too often)

Short cycling has many causes: oversized equipment, a badly placed thermostat or sensor, restricted airflow leading to icing, failing electrical parts, or refrigerant issues. Start with the cheap checks.

5 steps ~60 minmoderate

Guide · Air Conditioner

Air conditioner won't turn on (no display, no fan)

Confirm power from the outlet or breaker before blaming the unit. Room units often have a reset button on an LCDI/ALCI plug; mini-splits need power at the disconnect and a working remote.

5 steps ~20 mineasy

Guide · Air Conditioner

Outdoor fan or indoor fan runs but compressor doesn't (capacitor & contactor)

On central AC and many room units, a weak run/start capacitor or burned contactor is the usual cause. Test the capacitor µF against its label and the contactor coil and contacts. A compressor that still won't run with good parts is sealed-system territory.

5 steps ~45 minadvanced

Guide · Air Conditioner

Air conditioner loud noise or vibration

Most noise is mechanical and easy: loose panels, fan blade striking ice or the shroud, worn motor bearings, or a poorly supported window unit. Electrical buzzing at the condenser often points to a contactor or capacitor.

5 steps ~45 minmoderate

Guide · Air Conditioner

Remote or thermostat not responding

Start with batteries and line of sight, then test the unit with its own controls. On central systems, confirm the thermostat is powered (24 V) and actually calling.

4 steps ~20 mineasy

Guide · Air Conditioner

Mini-split indoor unit blinking light (reading the code)

A blinking pattern is a fault code. Count the blinks before you reset power, because a breaker reset erases the code. Then look it up for the brand and fix the cause.

4 steps ~30 minmoderate

Component test · Air Conditioner

Dual run capacitor (HVAC condenser): testing both sections

A dual capacitor has C (common), HERM (compressor) and FAN terminals with two µF ratings in one can. Test C-HERM and C-FAN separately against the label; one section can fail while the other is fine.

5 steps ~20 minmoderate

Component test · Air Conditioner

Contactor (HVAC): coil, contacts and voltage drop

The contactor closes line voltage to the compressor and fan when it gets 24 V on its coil. Check coil voltage, coil resistance, contact condition and voltage drop across closed contacts.

5 steps ~25 minmoderate

Component test · Air Conditioner

24 V control transformer (HVAC)

The control transformer steps line voltage down to about 24 V AC for the thermostat, board and contactor coil. Measure primary and secondary under power; a blown low-voltage fuse means a short in the 24 V wiring, not a bad transformer.

4 steps ~20 minmoderate

Component test · Air Conditioner

Mini-split outdoor inverter board: what is safe to check

Mini-split outdoor boards rectify line voltage to a high DC bus and drive the compressor and fan. Field checks are input power, communication, error codes and compressor winding balance. Board DC bus voltage is dangerous after shutdown.

5 steps ~60 minadvanced

Guide · Air Conditioner

Central AC shut off by the condensate float switch

Float switches cut the cooling circuit when condensate backs up, usually from an algae or dust clog in the drain line or a failed condensate pump. Clear the drain, let the switch dry/reset, and find out why it backed up. Never bypass the switch.

5 steps ~45 mineasy

Guide · Air Conditioner

Central AC won't come back after a power outage or breaker trip

After power returns, thermostats and some outdoor units hold off the compressor for a few minutes. If nothing starts after that, check the thermostat, both breakers, the outdoor disconnect, the float switch and the low-voltage fuse before suspecting parts damaged by a surge.

5 steps ~30 mineasy

Install · Air Conditioner

Mini-split install overview: mounting and electrical prep only (line set BLOCKED)

The handyman scope is limited to the indoor wall plate, the wall penetration, the outdoor pad or bracket and coordinating electrical work. Line-set connection, vacuum, refrigerant release or charging are EPA 608 work and BLOCKED; the outdoor disconnect and circuit are for a licensed electrician.

5 steps ~180 minadvanced

Install · Air Conditioner

Window air conditioner install and support bracket

Secure the unit so it cannot fall, give it the slight outward tilt the manual specifies (some models have a sloped base pan and need none), seal the side panels, and plug directly into a suitable outlet. Larger or heavier units should have an exterior support bracket.

5 steps ~60 mineasy

Guide · Air Conditioner

Central AC: indoor blower runs but outdoor unit won't start (24 V circuit check)

Work the 24 V circuit from the thermostat to the contactor coil. A tripped float switch, damaged outdoor thermostat cable or an open disconnect are far more common than a dead compressor.

6 steps ~45 minmoderate

Guide · Air Conditioner

Heat pump outdoor coil iced over (not defrosting)

Light frost that clears every hour or so is normal. A solid block of ice means defrost isn't starting or finishing. Check outdoor fan, defrost sensor and board with a forced defrost before suspecting refrigerant.

6 steps ~60 minadvanced

Guide · Air Conditioner

Heat pump blows cold in heat mode (or heats in cool mode)

The reversing valve is in the wrong position. Check the thermostat O/B setting first, then 24 V at the solenoid coil, then the coil itself. A valve that won't shift with a good energized coil is sealed-system work.

5 steps ~30 minmoderate

Guide · Air Conditioner

Portable AC shows water-full code or keeps filling

In humid weather or dry mode, a portable can collect water faster than it evaporates it. Drain and set up a continuous drain first; a code with an empty tank points to the float switch or internal pump.

4 steps ~30 mineasy

Guide · Air Conditioner

Mini-split communication error: interconnect wiring check

Most communication faults are wiring: swapped terminals, loose screws, splices or damaged cable, often after a new install or a storm. Check power, then terminations at both ends, then the data signal, before replacing a board.

5 steps ~60 minadvanced

Carrier · 2 codes

Daikin · 20 codes

Daikin · Air Conditioner

A1

Indoor PCB fault

The indoor control board has detected an internal fault.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

A3

Drain water level too high

The float in the drain pan tripped and stopped the unit.

Cross-checked

Daikin · Air Conditioner

A5

Freeze-up / high-pressure control

The indoor coil is too cold in cooling (or pressure too high in heating) and protection has kicked in.

Cross-checked

Daikin · Air Conditioner

A6

Indoor fan motor fault

The indoor fan motor is locked, overloaded or not reporting speed.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

C4

Indoor coil thermistor fault

The indoor heat exchanger thermistor is open, shorted or disconnected.

Cross-checked

Daikin · Air Conditioner

C9

Room / intake air thermistor fault

The suction (room) air thermistor is reading abnormally.

Cross-checked

Daikin · Air Conditioner

E5

Compressor overheat (overload protector)

The compressor overheated and its protection opened.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

E6

Compressor lock / start failure

The compressor failed to start or drew excessive current at start.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

E7

Outdoor fan motor fault

The outdoor DC fan motor is not running correctly.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

EA

Four-way (reversing) valve fault

The unit did not switch correctly between heat and cool.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

F3

Discharge pipe temperature too high

The compressor discharge line got too hot.

Cross-checked Licensed pro only

Daikin · Air Conditioner

H6

Compressor position-detection error

The inverter could not sense the compressor rotor position.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

H9

Outdoor air thermistor fault

The outdoor air temperature sensor reads out of range.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

J3

Discharge pipe thermistor fault

The discharge pipe sensor reads open or shorted.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

J6

Outdoor heat exchanger thermistor fault

The outdoor coil sensor reads open or shorted.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

L4

Inverter heat sink overheating

The outdoor inverter's heat sink (fin) is running too hot.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

L5

Inverter output overcurrent

The inverter detected a sudden overcurrent to the compressor.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

U0

Low refrigerant suspected

The system logic indicates insufficient refrigerant.

Cross-checked Licensed pro only

Daikin · Air Conditioner

U2

Supply voltage out of range

The inverter saw supply voltage too low or too high.

Cross-checked High-voltage / caution

Daikin · Air Conditioner

U4

Indoor-outdoor communication error

Signal transmission between indoor and outdoor units has failed.

Cross-checked High-voltage / caution

Frigidaire · 8 codes

Fujitsu · 17 codes

Fujitsu · Air Conditioner

11 (Operation 1 / Timer 1 blinks)

Serial communication error

Indoor and outdoor units are not communicating.

Cross-checked High-voltage / caution

Fujitsu · Air Conditioner

12

Wired remote communication error

The wired remote has not heard from the indoor unit for over a minute.

Cross-checked

Fujitsu · Air Conditioner

23

Indoor/outdoor combination error

The outdoor unit sees an indoor unit it does not accept, or miswiring.

Single source High-voltage / caution

Fujitsu · Air Conditioner

32

Indoor PCB memory error

The indoor board cannot read its memory.

Cross-checked

Fujitsu · Air Conditioner

41

Indoor room thermistor fault

The indoor room temperature thermistor is reading abnormally.

Cross-checked

Fujitsu · Air Conditioner

42

Indoor coil thermistor error

The indoor heat-exchanger sensor reads open, shorted or out of range.

Cross-checked

Fujitsu · Air Conditioner

51

Indoor fan motor fault

The indoor unit fan motor is not operating correctly.

Cross-checked High-voltage / caution

Fujitsu · Air Conditioner

53

Drain error

Drain/drain pump fault detected.

Cross-checked

Fujitsu · Air Conditioner

62

Outdoor main PCB memory error

The outdoor main board cannot access its memory.

Cross-checked High-voltage / caution

Fujitsu · Air Conditioner

63

Inverter error

The inverter board reported a fault.

Single source High-voltage / caution

Fujitsu · Air Conditioner

71

Discharge thermistor error

The compressor discharge sensor reads open or shorted.

Cross-checked High-voltage / caution

Fujitsu · Air Conditioner

73

Outdoor coil thermistor error

The outdoor heat-exchanger sensor reads open or shorted.

Cross-checked High-voltage / caution

Fujitsu · Air Conditioner

74

Outdoor ambient thermistor error

The outdoor air sensor reads open or shorted.

Cross-checked High-voltage / caution

Fujitsu · Air Conditioner

94

Compressor overcurrent (trip detection)

Repeated overcurrent trips after compressor start.

Cross-checked High-voltage / caution

Fujitsu · Air Conditioner

97

Outdoor fan motor error

The outdoor fan did not reach its minimum speed.

Cross-checked High-voltage / caution

Fujitsu · Air Conditioner

99

Four-way valve error

The reversing valve appears stuck or reversed.

Cross-checked High-voltage / caution

Fujitsu · Air Conditioner

A1

Discharge temperature too high

The compressor discharge temperature exceeded its limit.

Cross-checked Licensed pro only

GE · 7 codes

Gree · 15 codes

Gree · Air Conditioner

C5

Jumper cap / configuration error

The indoor board has no jumper cap or the wrong one. Common right after a board replacement.

Cross-checked

Gree · Air Conditioner

E1

High-pressure protection

The system tripped on high head pressure. Most often the outdoor coil cannot reject heat.

Cross-checked High-voltage / caution

Gree · Air Conditioner

E3

Low-pressure protection

The system tripped on low suction pressure. After airflow problems are ruled out, low charge or a leak is the usual cause.

Cross-checked Licensed pro only

Gree · Air Conditioner

E5

Overcurrent protection

The control saw current above its limit, usually tied to bad supply voltage or a strained compressor.

Cross-checked High-voltage / caution

Gree · Air Conditioner

E6

Indoor/outdoor communication fault

The indoor and outdoor boards are not exchanging data.

Cross-checked High-voltage / caution

Gree · Air Conditioner

E7

Mode conflict

Two indoor heads on one outdoor unit are asking for opposite modes (heat vs cool). Not a hardware fault.

Cross-checked

Gree · Air Conditioner

F1

Indoor room (ambient) sensor fault

The indoor return-air thermistor reads open or shorted.

Cross-checked

Gree · Air Conditioner

F2

Indoor coil (evaporator) sensor fault

The indoor coil thermistor reads open, shorted or out of range.

Cross-checked

Gree · Air Conditioner

F3

Outdoor ambient sensor fault

The outdoor air thermistor reads open or shorted.

Cross-checked High-voltage / caution

Gree · Air Conditioner

F4

Outdoor coil (tube) sensor fault

The outdoor coil thermistor reads open, shorted or out of range.

Cross-checked High-voltage / caution

Gree · Air Conditioner

F5

Discharge temperature sensor fault

The compressor discharge-line thermistor reads open, shorted or out of range.

Cross-checked High-voltage / caution

Gree · Air Conditioner

H1

Defrost in progress (status)

Normal display while the outdoor coil defrosts in heat mode. Only a concern if it shows very often or for very long.

Cross-checked

Gree · Air Conditioner

H5

IPM (power module) protection

The inverter power module tripped on excess current or temperature.

Cross-checked High-voltage / caution

Gree · Air Conditioner

L9

Power protection

The unit entered power protection after a surge or abnormal electrical condition.

Cross-checked High-voltage / caution

Gree · Air Conditioner

U3

DC bus voltage drop

The inverter detected the DC bus voltage falling below its limit.

Cross-checked High-voltage / caution

Haier · 1 codes

LG · 8 codes

Midea · 2 codes

Mitsubishi Electric · 12 codes

Mitsubishi Electric · Air Conditioner

E0 / E3 / E4

Remote / communication error

A communication fault between the controller and the indoor unit, or between units. Exact meaning varies by series.

Cross-checked High-voltage / caution

Mitsubishi Electric · Air Conditioner

E6

Indoor-outdoor communication error

The indoor unit is not receiving valid signals from the outdoor unit.

Cross-checked High-voltage / caution

Mitsubishi Electric · Air Conditioner

P1

Intake (return) air sensor fault

The intake/return air thermistor (TH1) is reading abnormally.

Cross-checked

Mitsubishi Electric · Air Conditioner

P2

Pipe (coil) sensor fault

The indoor liquid-pipe/coil thermistor (TH2) is open, shorted or disconnected.

Cross-checked

Mitsubishi Electric · Air Conditioner

P4

Drain sensor fault

The drain sensor is reading abnormally or the drain is blocked.

Cross-checked

Mitsubishi Electric · Air Conditioner

P5

Drain overflow / drain pump problem

Condensate level is high, usually because the drain pump is stuck, failed or the line is blocked.

Cross-checked

Mitsubishi Electric · Air Conditioner

P6

Freeze / overheat protection

The indoor coil got too cold (cooling) or too hot (heating), usually from poor airflow.

Cross-checked

Mitsubishi Electric · Air Conditioner

P8

Abnormal pipe temperature

The coil/pipe temperature is not changing the way the board expects during operation.

Cross-checked

Mitsubishi Electric · Air Conditioner

P9

Pipe (coil) thermistor error

One of the indoor coil/pipe thermistors reads open or shorted.

Cross-checked

Mitsubishi Electric · Air Conditioner

PA

Forced compressor stop

The compressor was stopped by protection logic (often drain or overload related).

Cross-checked High-voltage / caution

Mitsubishi Electric · Air Conditioner

U3 / U4

Outdoor thermistor open/short

An outdoor unit thermistor reads open or shorted.

Cross-checked High-voltage / caution

Mitsubishi Electric · Air Conditioner

UP / UF

Compressor overcurrent / locked compressor

The outdoor unit cut the compressor for overcurrent (UP) or a locked rotor (UF).

Cross-checked High-voltage / caution

MrCool · 8 codes

Pioneer · 5 codes

Samsung · 19 codes

Samsung · Air Conditioner

E101

Indoor communication error

The indoor unit lost communication (with the outdoor unit or its panel).

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E121

Indoor room temperature sensor error

The indoor room thermistor is open or shorted.

Cross-checked

Samsung · Air Conditioner

E122

Indoor coil inlet (EVAP IN) sensor error

The sensor on the inlet of the indoor coil is open or shorted.

Cross-checked

Samsung · Air Conditioner

E123

Indoor coil outlet (EVAP OUT) sensor error

The sensor on the outlet of the indoor coil is open or shorted.

Cross-checked

Samsung · Air Conditioner

E128 / E129

Coil sensor detached

The control judged that the EVAP IN (E128) or EVAP OUT (E129) sensor is no longer touching the pipe.

Cross-checked

Samsung · Air Conditioner

E154

Indoor fan error

The indoor fan motor is not running at the commanded speed.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E163

Option / EEPROM setting error

The indoor unit option code or setting data is wrong or missing.

Cross-checked

Samsung · Air Conditioner

E202

Indoor/outdoor communication error

The outdoor unit is not receiving data from the indoor unit.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E203

Outdoor main/inverter micro communication error

The main and inverter processors inside the outdoor unit are not communicating.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E221

Outdoor ambient sensor error

The outdoor air thermistor is open or shorted.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E231

Outdoor coil (condenser out) sensor error

The outdoor coil sensor is open or shorted.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E251

Discharge temperature sensor error

The compressor discharge thermistor is open or shorted.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E458

Outdoor fan error

The outdoor fan motor is not running correctly.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E461

Compressor start/operation failure

The inverter could not start or keep the compressor running.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E464

IPM overcurrent

The inverter power module saw excessive current.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E466

DC-link voltage under/over

The DC voltage inside the inverter is outside limits.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E474

Heat sink sensor error

The IPM heat sink temperature sensor reading is invalid.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E500

Heat sink / IPM overheat

The inverter power module ran too hot.

Cross-checked High-voltage / caution

Samsung · Air Conditioner

E554

Refrigerant leak detected

The system judged it has lost refrigerant charge.

Cross-checked Licensed pro only

Official manufacturer support