Furnaces
Control-board blink codes, igniters, flame sensors, pressure switches and limits. Gas side refer-only.
6 field manuals · 63 error codes · 15 diagnostic guides · 6 brands
Field service manuals
Diagnostic guides
Carrier / Bryant / Payne · 16 codes
Carrier / Bryant / Payne · Furnace
11
No fault stored
Shown when the stored-fault history has been cleared, or after a power interruption wiped the last code. Not a fault by itself.
Carrier / Bryant / Payne · Furnace
12
Blower on after power-up
The control powered up while a heat call was present (or after a power blip) and runs the blower for a short period before resuming normal sequence.
Carrier / Bryant / Payne · Furnace
13
Limit circuit lockout
The limit circuit opened repeatedly or stayed open too long, so the control locked out gas heat. It follows repeated code 33 events.
Carrier / Bryant / Payne · Furnace
14
Ignition lockout
The control tried to light and prove flame several times and failed every time, so it locked out. On these boards it usually auto-resets after about 3 hours.
Carrier / Bryant / Payne · Furnace
21
Gas heating lockout
The control detected a gas-valve circuit problem and locked out heat. This lockout does not reset by itself.
Carrier / Bryant / Payne · Furnace
22
Flame sensed with gas valve off
The control proved a flame while the gas valve was supposed to be closed. Treat it as a gas valve or flame-circuit hazard; confirm on the door legend for your model.
Carrier / Bryant / Payne · Furnace
23
Pressure switch did not open
At the start of a call, the pressure switch was already closed before the inducer ran, so the control will not start the sequence.
Carrier / Bryant / Payne · Furnace
24
Low-voltage fuse open
The fuse protecting the 24 V control circuit on the board has blown.
Carrier / Bryant / Payne · Furnace
31
Pressure switch did not close or reopened
The inducer was started but the pressure switch never proved draft, or it opened during the cycle.
Carrier / Bryant / Payne · Furnace
32
Draft safeguard / low-heat pressure / auxiliary limit open
On some models a draft safeguard switch, low-heat pressure switch or (downflow units) auxiliary limit opened. Exact meaning depends on the model.
Carrier / Bryant / Payne · Furnace
33
Limit circuit fault
A safety in the limit string (main limit, rollout, draft safeguard or blocked-vent switch, depending on model) opened. The blower runs to cool the unit before retrying.
Carrier / Bryant / Payne · Furnace
34
Ignition proving failure
The igniter worked and gas was called for, but the control did not sense flame (or not enough) within the trial time. After several tries it becomes code 14.
Carrier / Bryant / Payne · Furnace
41
Blower outside valid speed range
The control reports that the blower motor is not reaching or holding its commanded speed.
Carrier / Bryant / Payne · Furnace
42
Inducer outside valid speed range
The variable-speed inducer is not running at the speed the control expects.
Carrier / Bryant / Payne · Furnace
43
Pressure switch calibration fault
On variable-speed condensing units, the control could not calibrate the pressure switch at the expected inducer speed. On some two-stage models this code instead means the low-heat pressure switch is open.
Carrier / Bryant / Payne · Furnace
45
Control circuitry lockout
The control detected an internal fault and locked out; it may auto-reset after about an hour.
Goodman / Amana / Daikin · 10 codes
Goodman / Amana / Daikin · Furnace
1 flash
Ignition failure / lockout
The furnace failed to light or prove flame on its retries and has locked out.
Goodman / Amana / Daikin · Furnace
2 flashes
Pressure switch stuck closed
The pressure switch reads closed before the inducer starts, so the sequence will not begin.
Goodman / Amana / Daikin · Furnace
3 flashes
Pressure switch stuck open
The inducer runs but the pressure switch never closes, so the furnace will not ignite.
Goodman / Amana / Daikin · Furnace
4 flashes
High limit open
The main limit opened because the heat exchanger area got too hot, usually from low airflow.
Goodman / Amana / Daikin · Furnace
5 flashes
Flame sensed with no call for heat
Most sources list this as flame detected while the gas valve should be closed. Some older Amana boards use 5 flashes for an open rollout switch, so check the door legend.
Goodman / Amana / Daikin · Furnace
6 flashes
Rollout switch open (varies by board)
Two blog sources list this as an open flame rollout switch; one Amana listing uses 6 flashes for reversed polarity instead.
Goodman / Amana / Daikin · Furnace
7 flashes
Low flame signal
Flame is present but the signal reaching the board is weak.
Goodman / Amana / Daikin · Furnace
8 flashes
Board-specific (igniter / lockout / pressure switch cycling)
Sources disagree: listed as igniter circuit fault, ignition lockout, or pressure switch opened several times in one call (Amana HSI-2/50A55).
Goodman / Amana / Daikin · Furnace
Rapid continuous flashing
Reversed line polarity
The 120 V hot and neutral are reversed at the furnace, so flame sensing does not work correctly.
Goodman / Amana / Daikin · Furnace
Steady on
Internal control failure
The LED stays lit without flashing, indicating the control has failed internally.
Lennox · 15 codes
Lennox · Furnace
E223
Low pressure switch failed open
The low-fire pressure switch did not close when the control expected it to. Confirm against the legend on your furnace door.
Lennox · Furnace
E228
Pressure switch calibration unsuccessful
The control could not calibrate the pressure switch at startup.
Lennox · Furnace
E241
Flame sensed out of sequence
Flame is sensed when the gas valve should be closed.
Lennox · Furnace
E250
Limit switch circuit open
A limit in the safety string opened, usually from overheating; the unit waits and retries.
Lennox · Furnace
E290
Igniter circuit fault
The control detected a problem in the hot surface igniter circuit.
Lennox · Furnace
E292
Indoor blower cannot start
The blower motor failed to start, for example from an obstructed wheel or seized bearings.
Lennox · Furnace
E294
Inducer overcurrent
The combustion air inducer is drawing too much current.
Lennox · Furnace
LED1 fast flash / LED2 slow flash
Reversed line polarity
Line voltage hot and neutral are reversed (some boards also flag a poor ground).
Lennox · Furnace
LED1 fast flash + LED2 fast flash (together)
Normal heat operation
Both LEDs flashing fast together show a heat call in progress.
Lennox · Furnace
LED1 off / LED2 slow flash
Pressure switch open
The pressure switch did not close (some boards: opened repeatedly in one call). Often a vent or inducer issue.
Lennox · Furnace
LED1 on / LED2 on
Board failure or miswiring
Both LEDs steady on means the control failed or is wired incorrectly.
Lennox · Furnace
LED1 slow flash / LED2 fast flash
Low flame signal
Flame is present but the signal is weak.
Lennox · Furnace
LED1 slow flash / LED2 on
Primary or secondary limit open
A high-temperature limit is open, usually from restricted airflow.
Lennox · Furnace
LED1 slow flash + LED2 slow flash (together)
Power on, no heat call
Both LEDs flashing slowly together is the normal powered-up idle state.
Lennox · Furnace
LED1/LED2 alternating slow flash
Watchguard lockout
The control locked out after repeated failed ignitions or flame losses (Watchguard) and will retry after a timed delay.
Rheem / Ruud · 3 codes
Rheem / Ruud · Furnace
1 flash
Lockout or flame failure (varies)
One source lists a one-hour lockout after failed ignition; another lists low or no flame signal.
Rheem / Ruud · Furnace
2 flashes
Pressure switch open
The pressure switch did not close when the inducer ran.
Rheem / Ruud · Furnace
3 flashes
Limit switch open / overheat
The high limit opened because of overheating, usually low airflow.
Trane / American Standard · 12 codes
Trane / American Standard · Furnace
2 flashes
Lockout: ignition retries exceeded
The furnace failed to establish flame on its allowed retries and locked out.
Trane / American Standard · Furnace
3 flashes
Pressure switch fault
The pressure switch is not in the expected state for the sequence.
Trane / American Standard · Furnace
4 flashes
Open limit / over-temperature
A high-temperature limit opened, usually from restricted airflow.
Trane / American Standard · Furnace
5 flashes
Flame sensed with no gas valve signal
The control sees flame when there should be none.
Trane / American Standard · Furnace
6 flashes
Reversed polarity or poor ground
Line voltage polarity is wrong or the ground is poor.
Trane / American Standard · Furnace
7 flashes
Gas valve circuit error
The control detected a fault in the gas valve circuit.
Trane / American Standard · Furnace
8 flashes
Low flame sense signal
Flame is proving but with a weak signal.
Trane / American Standard · Furnace
9 flashes
Igniter problem (varies by board)
Two sites list this as an igniter fault; another lists an open inducer limit on some boards.
Trane / American Standard · Furnace
Fast flash
Normal: heat call
A fast steady blink means the control sees a heat call and is running its sequence.
Trane / American Standard · Furnace
Off
No power to the control
With the LED dark, the board is not powered.
Trane / American Standard · Furnace
Slow flash
Normal: no heat call
A slow steady blink is normal standby with no call for heat.
Trane / American Standard · Furnace
Steady on
Control failure
The LED is on without flashing: the control board has an internal problem.
York / Coleman / Luxaire · 7 codes
York / Coleman / Luxaire · Furnace
1 red flash
Flame present with gas valve off
Flame is sensed while the gas valve is not powered.
York / Coleman / Luxaire · Furnace
2 red flashes
Pressure switch stuck closed
The pressure switch reads closed before the inducer runs.
York / Coleman / Luxaire · Furnace
3 red flashes
Pressure switch stuck open
The pressure switch did not close after the inducer started.
York / Coleman / Luxaire · Furnace
4 red flashes
High limit open (some boards: 24 V fuse open)
The main limit opened; one source notes some boards also use this code for an open low-voltage fuse.
York / Coleman / Luxaire · Furnace
5 red flashes
Rollout or auxiliary limit open
A flame rollout switch or auxiliary limit opened. Rollout switches are often manual reset.
York / Coleman / Luxaire · Furnace
7 red flashes
Lockout: no ignition
The control failed to light after its tries and locked out; it retries after about an hour.
York / Coleman / Luxaire · Furnace
Rapid amber flash
Low flame signal
One source lists this as a possible low flame signal; check the sensor rod.