Water Heaters
Electric, gas and tankless: elements, thermostats, status codes and leaks. Gas side refer-only.
11 field manuals · 83 error codes · 19 diagnostic guides · 9 brands
Field service manuals
Diagnostic guides
A.O. Smith · 2 codes
A.O. Smith / State · 8 codes
A.O. Smith / State · Water Heater
1 flash (every 3 s)
Normal: pilot lit, control OK
A single blink repeating about every three seconds is the normal heartbeat: the pilot is proven and the gas control is working. It is not a fault.
A.O. Smith / State · Water Heater
2 flashes
Low thermopile voltage
The pilot is lit, but the thermopile is not delivering enough millivolts for the control to open the main burner valve.
A.O. Smith / State · Water Heater
4 flashes
Over-temperature shutdown (ECO)
The control sensed tank water above its safe limit and locked the burner off. The energy cut-off inside the control has acted.
A.O. Smith / State · Water Heater
5 flashes
Sensor failure
The gas control has detected a failure of its internal temperature sensor and will not run the burner.
A.O. Smith / State · Water Heater
7 flashes
Gas control failure
The gas control has diagnosed an internal failure of its own valve or electronics.
A.O. Smith / State · Water Heater
8 flashes
Knob OFF but thermopile still producing (possible stuck pilot valve)
The control knob is in the OFF position, yet the thermopile is still generating power. Either it has not cooled down yet, or the pilot is still burning because the pilot valve did not close.
A.O. Smith / State · Water Heater
No light
Control not powered: pilot out
The control is powered only by the thermopile, so with no pilot flame the status light stays dark. A dark LED normally means the pilot is not lit.
A.O. Smith / State · Water Heater
Steady (solid) light
Control turned OFF, thermopile cooling
The heater was running and the control knob has been turned OFF. The light stays on while the thermopile cools; this is not a fault by itself.
Bradford White · 9 codes
Bradford White · Water Heater
1 flash every 4 s (green)
Standby: pilot lit, burner off
Normal standby. The pilot is proven and the tank is satisfied, so the main burner is off.
Bradford White · Water Heater
1 flash every second (green)
Heating: main burner on
Normal call for heat. The main valve is open and the burner is lit.
Bradford White · Water Heater
2 flashes (yellow)
Low thermopile voltage
The pilot is on but the thermopile output is too low, so the control will not open the main valve.
Bradford White · Water Heater
4 flashes (red)
Temperature cut-out limit reached
Tank temperature went past the safety limit and the control shut down the burner. On some control versions a reset is required.
Bradford White · Water Heater
5 flashes (red)
Temperature sensor / electronics fault
The control has detected a fault with its water temperature sensor or its own electronics and will not fire.
Bradford White · Water Heater
6 flashes (red)
Door/chamber temperature sensor failure
The combustion chamber door sensor reports a fault.
Bradford White · Water Heater
9 flashes (red)
Tank leak detected
The accessory module detected water.
Bradford White · Water Heater
10 flashes (red)
Insufficient combustion air
Abnormal chamber temperature profile; airflow is restricted.
Bradford White · Water Heater
Solid ON (red)
Control in OFF mode
Not a fault: the setpoint was recently turned to OFF and the control is waiting for the thermopile to cool.
Navien · 6 codes
Navien · Water Heater
E003
Ignition failure
The unit tried to light but no flame was detected.
Navien · Water Heater
E004
False flame detected
The control sensed a flame when none should be present.
Navien · Water Heater
E012
Flame loss during operation
The flame went out while the unit was heating.
Navien · Water Heater
E016
Overheating
The unit sensed an overheat condition; reported causes are restricted flow or venting problems.
Navien · Water Heater
E030
Exhaust overheat
Exhaust temperature went too high.
Navien · Water Heater
E515
Circuit board (PCB) abnormal
The main board reported abnormal operation.
Noritz · 7 codes
Noritz · Water Heater
10
Combustion / exhaust problem
Combustion is abnormal and the unit reduced power; often linked to exhaust or burner condition. Troubleshot like code 90.
Noritz · Water Heater
11
Ignition failure
The unit could not light the burner. One of the three needed elements (gas, air, spark) is missing.
Noritz · Water Heater
12
Flame loss / weak flame
The burner lit but the flame was lost or too weak during operation.
Noritz · Water Heater
16
Outlet temperature spike (often scale)
Outlet water temperature rose sharply. Scale in the heat exchanger is the usual cause, because it makes the burner work harder.
Noritz · Water Heater
29
Condensate drain problem
Condensate is not draining (neutralizer or drain line blocked), and the unit stopped to keep the burner from flooding.
Noritz · Water Heater
73
Circuit board setting error
The board's settings are invalid, typically after a DIP switch or jumper was changed with power on, or a programming problem.
Noritz · Water Heater
90
Combustion abnormality
The air-fuel mixture is wrong. The unit has detected abnormal combustion.
Rheem · 2 codes
Rheem · Water Heater
A008
Dry-fire protection
The tank seems not fully filled; the heater locks itself out.
Rheem · Water Heater
A129
Upper element / relay circuit problem
Reported in the field as an upper element, relay or board issue; heater runs short of hot water.
Rheem / Ruud · 8 codes
Rheem / Ruud · Water Heater
11
No ignition
Ignition failed at startup. Gas supply is a common cause.
Rheem / Ruud · Water Heater
12
Flame failure / gas supply problem
Flame was lost during operation or gas supply is inadequate.
Rheem / Ruud · Water Heater
14
Overheating
Thermal protection tripped; the heater got too hot.
Rheem / Ruud · Water Heater
31
Inlet thermistor fault
The inlet water thermistor is open or faulty.
Rheem / Ruud · Water Heater
33
Outlet thermistor fault
The outlet water thermistor is open or faulty.
Rheem / Ruud · Water Heater
61
Combustion fan fault
The blower speed is abnormal or the fan failed.
Rheem / Ruud · Water Heater
65
Water flow control fault
The water volume control valve/motor is not working.
Rheem / Ruud · Water Heater
LC / 1L
Scale (lime) buildup
The heat exchanger needs descaling.
Rinnai · 27 codes
Rinnai · Water Heater
02
No burner operation during freeze protection
The unit wanted to fire in freeze-protection mode but the burner did not operate.
Rinnai · Water Heater
10
Air supply or exhaust blockage
The unit sensed a restriction in combustion air intake or exhaust venting and shut down.
Rinnai · Water Heater
11
No ignition
The burner did not light during the ignition attempt.
Rinnai · Water Heater
12
Flame failure
The burner lit but the flame was lost or not proven during operation.
Rinnai · Water Heater
14
Thermal fuse open (overheat)
A thermal fuse opened because the heat exchanger or burner area got too hot. The unit will not run until the cause is fixed and the fuse is addressed.
Rinnai · Water Heater
16
Over-temperature warning
Outlet water got hotter than the control allows and the unit shut down as a safety measure.
Rinnai · Water Heater
19
Electrical ground / short
A short to ground was detected in a component or harness, often right after water flow starts.
Rinnai · Water Heater
25
Condensate trap full
The condensate trap/drain is not draining and the unit has stopped to avoid flooding the burner.
Rinnai · Water Heater
30
Flammable vapor sensor
The flammable vapor sensor tripped or its circuit is faulty (models with the sensor).
Rinnai · Water Heater
32
Outlet water temperature sensor fault
The outgoing water temperature sensor reads out of range (open or shorted).
Rinnai · Water Heater
34
Combustion air temperature sensor
The air temperature thermistor (fan housing) reads out of range.
Rinnai · Water Heater
38
Exhaust gas temperature sensor
The exhaust temperature sensor reads out of range (condensing models).
Rinnai · Water Heater
41
Outdoor / freeze-protection sensor
The outdoor-air (freeze protection) thermistor is open or shorted. Some series still fire and flash 41 with the set point; others will not fire.
Rinnai · Water Heater
51
Inlet water thermistor
The inlet water thermistor is open or disconnected; the heater may keep running and flash 51.
Rinnai · Water Heater
54
High exhaust gas temperature
Exhaust temperature stayed above its limit (around 163°F on the documented models), so the heater cut firing then shut down.
Rinnai · Water Heater
57
Burner bi-metal open
One of the overheat bi-metal switches on the burner assembly opened. Needs the cause fixed, then a power reset.
Rinnai · Water Heater
58
Secondary heat exchanger bi-metal open
A bi-metal on the secondary (condensing) heat exchanger opened.
Rinnai · Water Heater
61
Combustion fan fault
The combustion fan is not running at the speed the control expects.
Rinnai · Water Heater
63
Recirculation / pump circuit problem
On pump/recirculation models: air in the loop, a plumbing leak, or wrong recirculation settings.
Rinnai · Water Heater
65
Water flow control fault
The water flow control valve is not operating correctly.
Rinnai · Water Heater
70
PC board fault
The controller found an internal or parameter fault.
Rinnai · Water Heater
72
Flame sensing (flame rod) fault
The flame rod circuit is faulty.
Rinnai · Water Heater
79
Water leak detected
The unit's leak sensor detected water inside the cabinet.
Rinnai · Water Heater
FF
Maintenance performed (history marker)
A record in the code history showing that maintenance was performed; not an active fault.
Rinnai · Water Heater
LC / LC0-LC9
Scale build-up in heat exchanger
The control estimates that lime scale is building up in the heat exchanger and is asking for a flush/descale.
Rinnai · Water Heater
SE
Cascade secondary unit error
Commercial cascade: the primary display flashes SE when a secondary heater has a code.
Rinnai · Water Heater
SS
Service reminder
Time-based service indicator set at installation; the heat exchanger is due for service (e.g., descaling).
Takagi / A.O. Smith tankless · 14 codes
Takagi / A.O. Smith tankless · Water Heater
101
Abnormal combustion warning
Combustion is abnormal (warning before 991).
Takagi / A.O. Smith tankless · Water Heater
111
Ignition failure
Burner did not light.
Takagi / A.O. Smith tankless · Water Heater
121
Flame loss
Flame went out during operation.
Takagi / A.O. Smith tankless · Water Heater
311
Outlet thermistor failure
Outlet water thermistor is open or shorted.
Takagi / A.O. Smith tankless · Water Heater
321
Inlet thermistor failure
Inlet water thermistor is open or shorted.
Takagi / A.O. Smith tankless · Water Heater
331
Mixing thermistor failure
Mixing (bypass) thermistor is open or shorted.
Takagi / A.O. Smith tankless · Water Heater
391
Air-fuel ratio rod failure
The air-fuel ratio rod signal is abnormal.
Takagi / A.O. Smith tankless · Water Heater
441
Flow sensor failure
Flow sensor fault (Easy-Link / Multi-Link systems).
Takagi / A.O. Smith tankless · Water Heater
551
Gas solenoid valve failure
A gas solenoid valve is abnormal.
Takagi / A.O. Smith tankless · Water Heater
611
Fan motor fault
Combustion fan motor is abnormal.
Takagi / A.O. Smith tankless · Water Heater
701
Computer board failure
The control board detected an internal fault.
Takagi / A.O. Smith tankless · Water Heater
721
False flame detected
Flame signal seen when none should exist.
Takagi / A.O. Smith tankless · Water Heater
741
Remote controller communication failure
Water heater and remote are not communicating.
Takagi / A.O. Smith tankless · Water Heater
991
Improper combustion
Combustion is unsafe; carbon monoxide risk.
Official manufacturer support