Outdoor fan or indoor fan runs but compressor doesn't (capacitor & contactor)
On central AC and many room units, a weak run/start capacitor or burned contactor is the usual cause. Test the capacitor µF against its label and the contactor coil and contacts. A compressor that still won't run with good parts is sealed-system territory.
Before you start
- 240 V is present at the condenser and contactor: kill the disconnect and verify zero volts.
- Discharge the capacitor before handling (short C to HERM and C to FAN through a resistor or insulated tool).
- Photograph wiring before removing the capacitor.
Diagnostic steps
Unlock all 5 steps with expected values
Full library + AI assistant for $34.90, one time.
Get lifetime accessOnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work.