500 guides

Repair guides

Pick a type, an appliance or a brand. Every guide lists the tools, the safety call-outs, the steps and the reading you should expect.

31 guides for LG

Refrigerators · 3

Washers · 6

Guide · Washer

LG LE code: testing the hall sensor and stator

LE means the board drove the motor but did not see rotation. Check the harness, then test the hall sensor (about 10 kΩ per channel and a pulsing signal), then the stator windings, before condemning the board.

5 steps ~60 minadvanced
Guide · Washer

Reading stored codes and service/test mode (overview)

Entry sequences differ by model and generation. Always confirm on the tech sheet inside the cabinet; the sequences below are examples reported for specific model families.

3 steps ~20 minmoderate
Guide · Washer

Top-load not agitating (fills and drains OK)

On older Whirlpool/Kenmore direct-drive top-loads, fill-and-drain-OK but no agitate/spin is the classic broken motor coupler. On newer models, look at the shift actuator/clutch, lid lock and motor.

4 steps ~60 minmoderate
Guide · Washer

Washer-dryer combo washes but does not dry

Combos are ventless and dry slowly. Clean the condenser/lint path, check load size and power (many need 240 V), then check heater or heat pump.

5 steps ~60 minmoderate
Component test · Washer

Rotor position sensor (direct-drive motors)

On direct-drive motors the rotor position sensor sits on the stator and tells the inverter where the rotor magnets are. A bad sensor, cracked connector or water ingress gives motor errors even with good windings.

5 steps ~45 minmoderate
Component test · Washer

Washer motor control unit / inverter board

Direct-drive and inverter washers use a motor control unit (MCU) that powers a 3-phase motor and reads a hall sensor or tach. Separate MCU, motor windings, hall sensor and harness before buying a board.

6 steps ~45 minadvanced

Dryers · 5

Ranges & Ovens · 1

Air Conditioners · 6

Guide · Air Conditioner

Mini-split communication error: interconnect wiring check

Most communication faults are wiring: swapped terminals, loose screws, splices or damaged cable, often after a new install or a storm. Check power, then terminations at both ends, then the data signal, before replacing a board.

5 steps ~60 minadvanced
Guide · Air Conditioner

Mini-split indoor unit blinking light (reading the code)

A blinking pattern is a fault code. Count the blinks before you reset power, because a breaker reset erases the code. Then look it up for the brand and fix the cause.

4 steps ~30 minmoderate
Guide · Air Conditioner

Portable AC shows water-full code or keeps filling

In humid weather or dry mode, a portable can collect water faster than it evaporates it. Drain and set up a continuous drain first; a code with an empty tank points to the float switch or internal pump.

4 steps ~30 mineasy
Guide · Air Conditioner

PTAC error codes: how to read and clear them

Most PTAC brands store fault codes that can be shown with a button combination on the control (for example GE Zoneline uses a MODE + another key sequence on some models). Read the active code, fix the cause, then clear it.

4 steps ~20 mineasy
Guide · Air Conditioner

PTAC not cooling (fan runs, air not cold)

Most PTAC no-cool calls are airflow (filter, coils), a wrong control setting or a failed compressor start component. Rule those out before suspecting the sealed system.

6 steps ~60 minmoderate
Component test · Air Conditioner

Mini-split outdoor inverter board: what is safe to check

Mini-split outdoor boards rectify line voltage to a high DC bus and drive the compressor and fan. Field checks are input power, communication, error codes and compressor winding balance. Board DC bus voltage is dangerous after shutdown.

5 steps ~60 minadvanced