York / Coleman / Luxaire TM9E 95% single-stage condensing gas furnaces: quick sheet

Covers: Johnson Controls (York) TM9E 95% AFUE single-stage multi-position condensing furnaces with a 5-speed standard ECM blower, 40-120 kBtu/h input. Model examples from the York technical guide: TM9E040A10MP12, TM9E060B12MP12, TM9E080C16MP12, TM9E100C20MP12, TM9E120D20MP12 (earlier ...MP11 revisions exist). Pattern: TM9E + input (040-120) + cabinet letter (A 14-1/2, B 17-1/2, C 21, D 24-1/2 in) + nominal airflow (10 = 1000, 12 = 1200, 16 = 1600, 20 = 2000 CFM) + MP + revision. Coleman and Luxaire sell Johnson Controls furnaces under their own names; confirm the model on the rating plate. The two-stage TM9V/TM9Y may show additional codes.

Cross-checkedBrands: York, Coleman, Luxaire6 components

The TM9E is a compact 33 in tall Category IV condensing furnace: aluminized-steel tubular primary heat exchanger, stainless secondary, hot surface ignition, a single-stage gas valve, a self-priming internal condensate trap, and a control board LED that flashes green, amber or red. It can be vented two-pipe (sealed combustion) or single-pipe with approved plastic or polypropylene vent systems. Filters are always external (no internal rack).

Safety first

  • Never bypass the pressure, limit or rollout switches.
  • A rollout trip (5 red) can mean flue gas spillage: check CO, do not reset repeatedly, refer.
  • Gas valve, manifold pressure and burner work are not covered here.

How it works

Heat call: the control checks the pressure switch is open, runs the inducer, waits for the switch to close, warms the igniter, opens the gas valve and proves flame.

Normal LED: slow green flash = idle, slow amber flash = heat call in progress.

The board keeps up to five fault codes; read them with the LAST ERROR button only when no thermostat call (heat, cool or fan) is active.

Condensate from the secondary heat exchanger drains through the internal trap; a blocked trap or drain can hold the pressure switch open.

Components & tests

Unlock all 6 components, specs, service mode and teardown

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

Official manufacturer documentation

Always confirm values against the tech sheet for the exact model.

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Condensing gas furnace with PVC vent pipes and metal ductwork in a utility room by Wtshymanski, CC BY-SA 4.0

Diagnostic guides for this appliance

Guide · Furnace

Furnace control boards: last-fault memory, fault recall and power-cycle rules (Carrier/Bryant, ICP, Goodman/Amana, Rheem/Ruud, Trane, Lennox)

Furnace boards show the current state on an LED or a 7-segment display, and many also keep a fault history. Some keep it only until power is removed; one Carrier-family description says stored codes clear on power loss or about 48 hours after the fault. Others have a fault-recall push button or recall terminal that replays recent faults. Read the LED through the door sight glass first; removing the blower door usually opens the door switch and drops power to the board.

7 steps ~15 mineasy
Guide · Furnace

Gas furnace fall inspection: what a handyman or appliance tech checks, and what goes to a licensed gas tech

Manufacturers and ENERGY STAR call for one professional heating check-up a year, ideally in early fall before the rush. The non-gas part of that visit (filter, airflow, condensate, venting condition, thermostat, blower and wiring, a supervised first fire) can be done and documented by a general tech. Anything that touches the gas valve, gas pressure, burner adjustment, combustion analysis or the heat exchanger belongs to a licensed gas/HVAC technician. This guide is inspection-only.

7 steps ~45 minmoderate
Guide · Furnace

Electric furnace or air handler with heat strips: fall pre-season check

Electric resistance heat has no burner or flue, so the fall check is about airflow, connections and proving every heat stage turns on. Measure supply voltage and the current of each element stage against the rating plate, look for heat-damaged wiring at the element terminals and sequencers or relays, and confirm the limits and blower work. Values come from the unit's rating plate and wiring diagram, not from this guide.

6 steps ~45 minadvanced

Other furnaces manuals

Manual · Furnace

Lennox SL280UHV / SL280UHNV 80% two-stage variable-speed gas furnaces: quick sheet

Lennox Dave Lennox Signature Collection SL280UHV (and the later SL280UHNV / SL280UHNVK revisions) 80% AFUE two-stage gas furnaces with a variable-speed blower and a two-stage, variable-speed integrated control with a seven-segment display. Upflow or horizontal (left or right). Model examples printed in Lennox literature: SL280UH070V36A, SL280UH090V36B, SL280UH090V48B, SL280UH110V60C, SL280UH135V60D. Reading the pattern from those examples (not from a Lennox nomenclature table), the three digits after UH are the input in kBtu/h, the two digits after V are the nominal cooling airflow in kBtu/h (36 = 3 ton, 48 = 4 ton, 60 = 5 ton) and the last letter is the cabinet width (A 14-1/2 in, B 17-1/2 in, C 21 in, D 24-1/2 in). Search terms: SL280UHV, SL280UH, SL280UHNV, Lennox 280 two-stage. For the Lennox ML180/EL180 80% and ML196/EL296 condensing furnaces see the separate quick sheets.

7 components5 common failuresLennox
Manual · Furnace

York / Coleman / Luxaire TM8E and TMLE 80% single-stage ECM gas furnaces: quick sheet

Johnson Controls TM8E (standard) and TMLE (low NOx) 80% single-stage multi-position furnaces with a 5-speed standard ECM blower, 40-130 kBtu/h. Model examples from the technical guide: TM8E040A12MP11, TM8E060A12MP11, TM8E080B12MP11, TM8E100C16MP11, TM8E120C20MP11, TM8E130D20MP11. Pattern: TM8E/TMLE + input + cabinet letter (A 14-1/2, B 17-1/2, C 21, D 24-1/2 in) + nominal airflow (12, 16, 20 = 1200, 1600, 2000 CFM) + MP + revision. Older TG8S and the two-stage TM8V are related families with their own literature.

4 components3 common failuresYork, Coleman, Luxaire
Manual · Furnace

Goodman / Amana GMVM97, GCVM97, AMVM97 modulating 97-98% furnaces: quick sheet

Goodman and Amana modulating condensing furnaces with a dual 7-segment display: GMVM97 (upflow/horizontal), GCVM97 (downflow/horizontal) and Amana AMVM97 / ACVM97. Goodman nomenclature: G (brand) + M (upflow/horizontal) or C (downflow/horizontal) + V (variable-speed ECM, ComfortBridge on newer units) + M (modulating valve) + 97 (AFUE class) + input (060, 080, 100, 120) + max airflow digit (3 = 1200, 4 = 1600, 5 = 2000 CFM) + cabinet letter (B 17-1/2, C 21, D 24-1/2 in) + N (low NOx) + revision, e.g. GMVM970603BN, GMVM971005CN. Older revisions are ComfortNet communicating; newer ones (2018+) use ComfortBridge with Bluetooth and the CoolCloud app. For the GM9S96 / GMVC96 see the separate quick sheet.