7 components coveredField manual · Furnace
Lennox SL280UHV / SL280UHNV 80% two-stage variable-speed gas furnaces: quick sheet
Covers: Lennox Dave Lennox Signature Collection SL280UHV (and the later SL280UHNV / SL280UHNVK revisions) 80% AFUE two-stage gas furnaces with a variable-speed blower and a two-stage, variable-speed integrated control with a seven-segment display. Upflow or horizontal (left or right). Model examples printed in Lennox literature: SL280UH070V36A, SL280UH090V36B, SL280UH090V48B, SL280UH110V60C, SL280UH135V60D. Reading the pattern from those examples (not from a Lennox nomenclature table), the three digits after UH are the input in kBtu/h, the two digits after V are the nominal cooling airflow in kBtu/h (36 = 3 ton, 48 = 4 ton, 60 = 5 ton) and the last letter is the cabinet width (A 14-1/2 in, B 17-1/2 in, C 21 in, D 24-1/2 in). Search terms: SL280UHV, SL280UH, SL280UHNV, Lennox 280 two-stage. For the Lennox ML180/EL180 80% and ML196/EL296 condensing furnaces see the separate quick sheets.
The SL280UHV is a non-condensing 80% furnace with two-stage gas heat, a variable-speed indoor blower and an integrated control that works either with conventional 24 V thermostats (set by DIP switches and clippable links) or with a Lennox communicating thermostat (all settings then come from the thermostat and the DIP switches are ignored). Diagnosis is done on the control's seven-segment LED, which shows status, target airflow and E-codes, and on a push button that opens the stored-code menu and a flame-current readout in microamps.
Safety first
- Never jumper a pressure switch, limit or rollout.
- E200 (rollout) and E241/E275 (flame out of sequence) are gas safety faults: shut down and refer to a licensed gas technician.
- Gas valve, manifold pressure and burner adjustments are not covered here.
How it works
On a heat call the control proves the low pressure switch open, starts the inducer, waits for the low switch to close, heats the hot surface ignitor and opens first stage of the gas valve. Flame must be proven by the flame sensor or the control retries and finally goes into a soft lockout (E270).
With a two-stage thermostat (DIP switch 1 OFF, factory setting) W2 calls second stage. With a single-stage thermostat (DIP switch 1 ON) the control adds second stage after a timed delay set by DIP switch 2.
Lennox's 'watchguard' feature automatically resets an ignition lockout after one hour of continuous heat demand by breaking and remaking the demand.
If the low-fire pressure switch does not close in time the control may light on high fire instead (E229, information only). If airflow is restricted the blower runs in cutback and the control can lower the firing rate (E311/E312 warnings).
The control stores the last 10 codes in non-volatile memory, so they survive a power loss.
Components & tests
Unlock all 7 components, specs, service mode and teardown
Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.
Get lifetime accessOfficial manufacturer documentation
Always confirm values against the tech sheet for the exact model.
OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Large stainless refrigerator set flush between kitchen cabinets by Alex Qian, Pexels License