GE JVM7195 (SK/DK/EK/SF) 1.9 cu ft sensor OTR microwave: quick sheet

Covers: GE JVM7195SKSS and its color/generation variants (DK, EK, SF and others). Some older JVM7195SF listings show a 3-speed 300 CFM vent, so check the exact suffix. GE OTR codes in the library (F1-F10, H97-H99) apply.

Cross-checkedBrands: GE6 components

GE's long-running 1.9 cu ft OTR with sensor cooking, a 4-speed 400 CFM vent (SK generation), melt and steam-clean functions. It sits above the JVM3160 (already in the library). Typical calls: no heat, door switch/fuse, vent motor or light, and keypad faults.

Safety first

  • CAUTION: the high-voltage capacitor can hold a lethal charge after the unit is unplugged. Only a trained tech opens the cabinet: unplug, wait, then discharge the capacitor with an insulated discharge tool before touching the HV section (transformer, capacitor, diode, magnetron).
  • Never run the oven with the wrapper or panels off, with an interlock defeated, or empty; never take live readings in the HV circuit.
  • After any door, hinge, latch or interlock work, confirm the door closes squarely and run a leakage survey (see microwave-leakage-limit-interlock-check-after-door-repair).
  • OTR units are heavy and hang on a wall plate plus top-cabinet bolts: two people, and support the unit before removing the top bolts.

How it works

Standard HV circuit rated 1,000 W (IEC 705 test).

Sensor cooking ends programs from the humidity sensor reading.

Vent is convertible (recirculate with the GE JX81 charcoal kit, or outside top/rear with a 3-1/4 x 10 in duct or 6 in round through a transition).

Reset Filter reminder on GE OTRs is a 6-month timer cleared by holding Reset Filter about 3 seconds.

Components & tests

Unlock all 6 components, specs, service mode and teardown

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

Official manufacturer documentation

Always confirm values against the tech sheet for the exact model.

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Over-the-range microwave mounted above a stainless electric range by Curtis Adams, Pexels License

Diagnostic guides for this appliance

Guide · Microwave

Microwave interior paint peeling, chipped or rusted (when to stop using it)

The cavity coating protects the steel; once bare metal is exposed it can rust and act as an arcing point, and flaking paint can fall into food. Small, isolated chips on an otherwise sound cavity can sometimes be touched up with a coating made for microwave cavities, fully cured before use. Widespread peeling, rust that has pitted or holed the metal, or any damage to the door, choke or seal area means the oven should be retired. Never use ordinary paint.

6 steps ~30 mineasy
Guide · Microwave

Over-the-range microwave duct run: size, equivalent length and when to recirculate instead

OTR microwave blowers are small, so the duct decides how well they vent. The common target on manufacturer install sheets is a 3-1/4 x 10 in rectangular duct or a round duct of at least 6 in through a rectangular-to-round transition, with the whole run kept under the maker's equivalent-length limit (GE sheets seen: 120 or 140 equivalent feet depending on the document). Every fitting counts as extra feet. This guide shows how to add up a run before you cut holes, and when the honest answer is to leave the unit on recirculate with a charcoal filter.

6 steps ~30 minmoderate
Guide · Microwave

Microwave door, interlock and leakage: what the federal standard requires and what to check after a door or switch repair

US microwave ovens are built to the FDA performance standard (21 CFR 1030.10): leakage may not exceed 1 mW/cm² as sold and 5 mW/cm² for the life of the oven, measured about 5 cm (2 in) from the surface, and every oven must have two independent interlocks plus a monitoring system that stops the oven if the interlocks fail. In the field that means a damaged door, hinge or seal is a stop-use condition, every interlock part goes back exactly as designed, and a door or switch repair should end with a leakage survey using a microwave survey meter. This guide covers the checks; it does not cover high-voltage work beyond the standard discharge warning.