8 components coveredField manual · Fundamentals
Control board output devices: relays, triacs and transistor drivers, and how loads kill them
Covers: Output switching parts on appliance control boards (washers, dryers, dishwashers, refrigerators, ranges, microwaves): electromechanical relays, triacs with their snubbers and opto-isolators, and transistor/MOSFET drivers for DC loads. Explains failure patterns and what to measure; no board-level repair.
Every load on a board is turned on by an output device. Relays fail with burnt or welded contacts, triacs usually fail shorted, and transistor drivers die when a DC load shorts. In almost every case the output died because of the load it drives, so the load must be checked before a new board goes in. This chapter also explains why an 'off' triac output can read full voltage on a meter.
Safety first
- Output checks are live-voltage measurements: insulated probes, one hand where possible, no jewelry.
- A shorted output can energize a load even with the appliance 'off' at the controls; unplug or open the breaker before touching loads.
- Handle boards by the edges with an ESD strap.
How it works
Relays: the board's logic energizes a small coil (often 12 V DC) through a driver transistor; the coil pulls contacts closed that carry the line-voltage load. Used for heavy or inductive loads such as heaters, compressors and motors. A click proves only that the coil moved.
Triacs: solid-state AC switches used for smaller AC loads such as water valves, drain pumps, dispenser motors, door locks and fans. A small gate signal (usually through an opto-isolator) turns the triac on; it turns off when the AC current falls to zero. An RC snubber across the triac helps it turn off cleanly with inductive loads.
Transistor and MOSFET drivers switch low-voltage DC loads (DC fans, LEDs, stepper and BLDC fan motors, some valves). They often have no visible fuse.
Inrush is what kills outputs: motors, transformers, solenoids and capacitive loads draw several times their running current at switch-on. Contacts arc and can weld; semiconductor junctions overheat. A shorted or low-resistance load does the same thing every time it is switched.
Failure modes: relay contacts either burn open (load never runs) or weld shut (load never stops). Triacs most often fail shorted, either fully or in one half of the AC wave; open-circuit triac failures are less common. A shorted output keeps the load energized whenever the appliance has power.
Components & tests
Unlock all 8 components, specs, service mode and teardown
Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.
Get lifetime accessOfficial manufacturer documentation
Always confirm values against the tech sheet for the exact model.
- CPSC recalls search
- SaferProducts.gov recall and incident search
- Whirlpool Corporation recall information
- GE Appliances recalls
- Frigidaire recall information
- Water heater and boiler recall lookup (A. O. Smith / Lochinvar)
- EPA Section 608 technician certification types
- OSHA control of hazardous energy (lockout/tagout)
- CPSC carbon monoxide information center
OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Clothes dryer with its vent duct in a small laundry closet by Introspectivedsgn, Pexels License