York YCJD (13 SEER) and YCJF (14.5 SEER) single-stage air conditioners (R-410A, Johnson Controls): quick sheet

Covers: York (Johnson Controls Unitary Products) single-stage R-410A split condensing units: YCJD 13 SEER (sizes 18-60, technical guide 840569-YTG-C-1112) and YCJF 14.5 SEER (sizes 18-60, technical guide 700695-YTG-B-0812). Model string example YCJD36S41S1HE: capacity 18-60 (kBtu/h) + S41S1 or S41S2 configuration, then optional H = factory hard start kit, E = ElectroFin coated coil. Coleman and Luxaire sell Johnson Controls platforms under their own prefixes; read the nameplate and match the technical guide. Newer SEER2 York lines (YC2E, YC3, R-454B) are different products. Search terms: YCJD36S41S1, YCJD24S41S1H, YCJF36S41S1, York 13 SEER condenser hard start.

Single sourceBrands: York, Johnson Controls4 components

Value-tier York condensers. The YCJD uses a rotary (18), reciprocating (24-48) or scroll (60) compressor; the YCJF uses scroll compressors in all sizes. The big service point on YCJD: York says sizes 18-48 need a hard start kit when matched to a TXV indoor coil (models ending in H have it installed at the factory). Otherwise these are contactor / capacitor / fan / compressor units with 24 V control.

Safety first

  • Lock out power; discharge start and run capacitors.
  • Refrigerant work is blocked: EPA 608-certified technician.

How it works

Y from the thermostat closes the contactor; line voltage runs the compressor and the PSC fan through the run capacitor.

YCJD with a TXV (non-bleed) indoor coil: the compressor starts against pressure, so York requires a hard start kit on sizes 18-48. YCJF scroll models do not need one with a TXV per York's table.

York also lists a start assist kit (S1-2SA067*) for low-voltage areas and S1-1TVM series TXV kits.

Components & tests

Unlock all 4 components, specs, service mode and teardown

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

Official manufacturer documentation

Always confirm values against the tech sheet for the exact model.

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Smooth glass electric cooktop built into a wooden counter by Max Vakhtbovych, Pexels License

Diagnostic guides for this appliance

Other air conditioners manuals

Manual · Air Conditioner

Carrier Infinity Greenspeed 24VNA6 air conditioner and 25VNA4 heat pump (variable speed): quick sheet

Carrier Infinity Greenspeed Intelligence variable-speed outdoor units: 24VNA6 air conditioner (up to 26 SEER) and 25VNA4 heat pump (up to 24 SEER, up to 13 HSPF), 2-5 ton. Nomenclature from the service manual: 24 = AC, 25 = HP; V = variable speed; N = Infinity series; A = Puron (R-410A); 6 / 4 = SEER tier; two digits = nominal capacity (e.g. 36 = 36,000 BTU/h); voltage digit 3 = 208/230-1; compressor ID 4 = variable-speed scroll, 5 = variable-speed rotary. Serial format: week + year + plant letter + sequence (e.g. 0118E00001). Other 24VNA families (24VNA0, 24VNA9) use different software and code lists.

5 components4 common failuresCarrier
Manual · Air Conditioner

Trane XV20i / XV18 variable-speed outdoor units (4TTV0 AC, 4TWV0 heat pump, ComfortLink II): quick sheet

Trane variable-speed TruComfort / ComfortLink II communicating outdoor units: 4TTV0 air conditioners (XV20i family, e.g. 4TTV0024A1000C, 4TTV0036, 4TTV0048, 4TTV0060, 4TTV0061) and 4TWV0 heat pumps (Service Facts 4T-V0-SF). They use an Integrated Variable Speed Control (IVSC) board and a Communicating Display Assembly (CDA) in the outdoor unit. Distributor listings note several 4TTV0 revisions; confirm the full model on the nameplate before ordering parts. Single-stage XR14/XR16 units are on a separate sheet.

4 components3 common failuresTrane
Manual · Air Conditioner

Lennox XC21 air conditioner and XP21 heat pump (Dave Lennox Signature, iComfort-enabled): quick sheet

Lennox XC21 (air conditioner, service literature Corp. 1007-L2) and XP21 (heat pump, Corp. 1031-L7), 2, 3, 4 and 5 ton, R-410A, expansion valve indoor coils only. Both use an A175 main control (outdoor control part number 101798-xx) that works in communicating (iComfort) or conventional 24 V mode, plus a separate fan motor control. The XP21 literature describes a two-stage scroll compressor; the 2018 XC21 literature describes the compressor as one-stage while the same control section covers two-stage units, so confirm staging on the nameplate. For ML14XC1/EL16XC1 single-stage units see the separate sheet.

4 components3 common failuresLennox
York YCJD (13 SEER) and YCJF (14.5 SEER) single-stage air conditioners (R-410A, Johnson Controls): quick sheet · OnCall Tech