Field manual · Air Conditioner

Rheem Classic Plus RA17 two-stage EcoNet-enabled air conditioner (RA1724-RA1760AJ2CB): quick sheet

Covers: Rheem Classic Plus RA17 17 SEER two-stage split air conditioners, R-410A: RA1724AJ2CB (2 ton), RA1736AJ2CB (3 ton), RA1748AJ2CB (4 ton), RA1760AJ2CB (5 ton), 208/230 V single phase. Model string per Rheem's spec sheet: R (Rheem) + A (air conditioner) + 17 (SEER) + capacity (24, 36, 48, 60) + major series (A first design) + voltage (J = 1 ph 208-230/60, C = 3 ph) + 2 (two-stage) + C (communicating) + minor series (B = high- and low-pressure control). The Ruud-branded equivalent uses the same RA-style platform; check the nameplate. Single-stage RA13/RA14/RA16 have their own sheet. Search terms: RA1736AJ2CB, RA1724AJ2NB, Rheem RA17, Rheem Classic Plus two stage, EcoNet condenser.

Single sourceBrands: Rheem, Ruud4 components

The RA17 runs a two-stage Copeland UltraTech scroll compressor (about 67 % and 100 % capacity per Rheem). It can be wired in fully communicating EcoNet mode (four wires E1, E2, R, C to an EcoNet thermostat or control center with an EcoNet furnace or air handler) or as a conventional two-stage unit (Y1, Y2, C). Most problems are wiring/mode setup, the two-stage solenoid circuit, capacitor and fan, and pressure-switch trips.

Safety first

  • Lock out power; capacitors hold a charge.
  • Refrigerant and charging work is blocked: refer to an EPA 608-certified technician.

How it works

Communicating mode: the outdoor control talks over E1/E2 with the indoor unit and EcoNet thermostat, which also show alarms and history.

Conventional mode: Y1 runs low stage, Y2 runs high stage (wiring figures in the spec sheet show a typical two-stage thermostat with Y1, Y2, C and R).

High- and low-pressure controls are standard (minor series B).

Low-ambient cooling down to about 0 °F requires Rheem's low-ambient kit, with crankcase heater and freeze-stat recommended on compressors fitted with that kit.

Components & tests

Unlock all 4 components, specs, service mode and teardown

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

Official manufacturer documentation

Always confirm values against the tech sheet for the exact model.

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Outdoor condensing unit with a large fan on a steel stand by ready made, Pexels License

Diagnostic guides for this appliance

Other air conditioners manuals

Manual · Air Conditioner

Carrier Infinity Greenspeed 24VNA6 air conditioner and 25VNA4 heat pump (variable speed): quick sheet

Carrier Infinity Greenspeed Intelligence variable-speed outdoor units: 24VNA6 air conditioner (up to 26 SEER) and 25VNA4 heat pump (up to 24 SEER, up to 13 HSPF), 2-5 ton. Nomenclature from the service manual: 24 = AC, 25 = HP; V = variable speed; N = Infinity series; A = Puron (R-410A); 6 / 4 = SEER tier; two digits = nominal capacity (e.g. 36 = 36,000 BTU/h); voltage digit 3 = 208/230-1; compressor ID 4 = variable-speed scroll, 5 = variable-speed rotary. Serial format: week + year + plant letter + sequence (e.g. 0118E00001). Other 24VNA families (24VNA0, 24VNA9) use different software and code lists.

5 components4 common failuresCarrier
Manual · Air Conditioner

Trane XV20i / XV18 variable-speed outdoor units (4TTV0 AC, 4TWV0 heat pump, ComfortLink II): quick sheet

Trane variable-speed TruComfort / ComfortLink II communicating outdoor units: 4TTV0 air conditioners (XV20i family, e.g. 4TTV0024A1000C, 4TTV0036, 4TTV0048, 4TTV0060, 4TTV0061) and 4TWV0 heat pumps (Service Facts 4T-V0-SF). They use an Integrated Variable Speed Control (IVSC) board and a Communicating Display Assembly (CDA) in the outdoor unit. Distributor listings note several 4TTV0 revisions; confirm the full model on the nameplate before ordering parts. Single-stage XR14/XR16 units are on a separate sheet.

4 components3 common failuresTrane
Manual · Air Conditioner

Lennox XC21 air conditioner and XP21 heat pump (Dave Lennox Signature, iComfort-enabled): quick sheet

Lennox XC21 (air conditioner, service literature Corp. 1007-L2) and XP21 (heat pump, Corp. 1031-L7), 2, 3, 4 and 5 ton, R-410A, expansion valve indoor coils only. Both use an A175 main control (outdoor control part number 101798-xx) that works in communicating (iComfort) or conventional 24 V mode, plus a separate fan motor control. The XP21 literature describes a two-stage scroll compressor; the 2018 XC21 literature describes the compressor as one-stage while the same control section covers two-stage units, so confirm staging on the nameplate. For ML14XC1/EL16XC1 single-stage units see the separate sheet.

4 components3 common failuresLennox
Rheem Classic Plus RA17 two-stage EcoNet-enabled air conditioner (RA1724-RA1760AJ2CB): quick sheet · OnCall Tech