Field manual · Air Conditioner

ICP Tempstar N4A5 15 SEER single-stage air conditioner (R-410A; Heil / Comfortmaker family): quick sheet

Covers: International Comfort Products (Carrier group) single-stage split air conditioners sold as Tempstar N4A5 (15 SEER class), 1.5 to 5 ton, R-410A. Model string per the ICP spec sheet: brand letter (N or T for Tempstar lines in this sheet) + 4 (R-410A) + A (air conditioner; H = heat pump) + 5 (15 SEER nominal) + capacity (18, 24, 30, 36, 42, 48, 60) + feature letter (A standard grille, G coil guard grille, C coastal) + voltage letter (K = 208/230-1-60, H = 208/230-3-60, L = 460-3, S = 575-3) + sales code / engineering revision, e.g. N4A518GKC, N4A536GKC, N4A548GKC. ICP sells parallel platforms under Heil, Comfortmaker, Arcoaire and KeepRite with their own brand letters; confirm on the nameplate. Later N4A5S...AKAWA units carry SEER2 ratings and may differ. Search terms: N4A536GKC, N4A524GKC, Tempstar N4A5, Heil N4A5, Comfortmaker N4A5.

Single sourceBrands: Tempstar, Heil, Comfortmaker, ICP4 components

Simple 24 V-controlled scroll condensing unit with a direct-drive propeller fan and a hard shut-off TXV-matched indoor coil. No outdoor board on the cooling-only model: diagnosis is contactor, capacitor, fan, compressor and the 24 V call. ICP lists a minimum cooling ambient of 55 °F without accessories.

Safety first

  • Lock out power; discharge capacitors.
  • Use copper wire from the disconnect to the unit (ICP).
  • Refrigerant work is blocked: EPA 608-certified technician.

How it works

Thermostat Y and C from the indoor unit energize the contactor; ICP notes the 24 V control circuit needs an external (indoor) power source.

Contactor feeds the scroll compressor and PSC fan motor through the run capacitor; all motors and compressors have internal overload protection.

Cooling operating range per the spec sheet: 55 °F to 125 °F outdoor (low-ambient kit needed below that).

Components & tests

Unlock all 4 components, specs, service mode and teardown

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

Official manufacturer documentation

Always confirm values against the tech sheet for the exact model.

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Air-source heat pump outdoor unit beside a house in the snow by PeterEastern, CC BY-SA 4.0

Diagnostic guides for this appliance

Other air conditioners manuals

Manual · Air Conditioner

Carrier Infinity Greenspeed 24VNA6 air conditioner and 25VNA4 heat pump (variable speed): quick sheet

Carrier Infinity Greenspeed Intelligence variable-speed outdoor units: 24VNA6 air conditioner (up to 26 SEER) and 25VNA4 heat pump (up to 24 SEER, up to 13 HSPF), 2-5 ton. Nomenclature from the service manual: 24 = AC, 25 = HP; V = variable speed; N = Infinity series; A = Puron (R-410A); 6 / 4 = SEER tier; two digits = nominal capacity (e.g. 36 = 36,000 BTU/h); voltage digit 3 = 208/230-1; compressor ID 4 = variable-speed scroll, 5 = variable-speed rotary. Serial format: week + year + plant letter + sequence (e.g. 0118E00001). Other 24VNA families (24VNA0, 24VNA9) use different software and code lists.

5 components4 common failuresCarrier
Manual · Air Conditioner

Trane XV20i / XV18 variable-speed outdoor units (4TTV0 AC, 4TWV0 heat pump, ComfortLink II): quick sheet

Trane variable-speed TruComfort / ComfortLink II communicating outdoor units: 4TTV0 air conditioners (XV20i family, e.g. 4TTV0024A1000C, 4TTV0036, 4TTV0048, 4TTV0060, 4TTV0061) and 4TWV0 heat pumps (Service Facts 4T-V0-SF). They use an Integrated Variable Speed Control (IVSC) board and a Communicating Display Assembly (CDA) in the outdoor unit. Distributor listings note several 4TTV0 revisions; confirm the full model on the nameplate before ordering parts. Single-stage XR14/XR16 units are on a separate sheet.

4 components3 common failuresTrane
Manual · Air Conditioner

Lennox XC21 air conditioner and XP21 heat pump (Dave Lennox Signature, iComfort-enabled): quick sheet

Lennox XC21 (air conditioner, service literature Corp. 1007-L2) and XP21 (heat pump, Corp. 1031-L7), 2, 3, 4 and 5 ton, R-410A, expansion valve indoor coils only. Both use an A175 main control (outdoor control part number 101798-xx) that works in communicating (iComfort) or conventional 24 V mode, plus a separate fan motor control. The XP21 literature describes a two-stage scroll compressor; the 2018 XC21 literature describes the compressor as one-stage while the same control section covers two-stage units, so confirm staging on the nameplate. For ML14XC1/EL16XC1 single-stage units see the separate sheet.

4 components3 common failuresLennox
ICP Tempstar N4A5 15 SEER single-stage air conditioner (R-410A; Heil / Comfortmaker family): quick sheet · OnCall Tech