4 components coveredField manual · Air Conditioner
ICP Tempstar N4A5 15 SEER single-stage air conditioner (R-410A; Heil / Comfortmaker family): quick sheet
Covers: International Comfort Products (Carrier group) single-stage split air conditioners sold as Tempstar N4A5 (15 SEER class), 1.5 to 5 ton, R-410A. Model string per the ICP spec sheet: brand letter (N or T for Tempstar lines in this sheet) + 4 (R-410A) + A (air conditioner; H = heat pump) + 5 (15 SEER nominal) + capacity (18, 24, 30, 36, 42, 48, 60) + feature letter (A standard grille, G coil guard grille, C coastal) + voltage letter (K = 208/230-1-60, H = 208/230-3-60, L = 460-3, S = 575-3) + sales code / engineering revision, e.g. N4A518GKC, N4A536GKC, N4A548GKC. ICP sells parallel platforms under Heil, Comfortmaker, Arcoaire and KeepRite with their own brand letters; confirm on the nameplate. Later N4A5S...AKAWA units carry SEER2 ratings and may differ. Search terms: N4A536GKC, N4A524GKC, Tempstar N4A5, Heil N4A5, Comfortmaker N4A5.
Simple 24 V-controlled scroll condensing unit with a direct-drive propeller fan and a hard shut-off TXV-matched indoor coil. No outdoor board on the cooling-only model: diagnosis is contactor, capacitor, fan, compressor and the 24 V call. ICP lists a minimum cooling ambient of 55 °F without accessories.
Safety first
- Lock out power; discharge capacitors.
- Use copper wire from the disconnect to the unit (ICP).
- Refrigerant work is blocked: EPA 608-certified technician.
How it works
Thermostat Y and C from the indoor unit energize the contactor; ICP notes the 24 V control circuit needs an external (indoor) power source.
Contactor feeds the scroll compressor and PSC fan motor through the run capacitor; all motors and compressors have internal overload protection.
Cooling operating range per the spec sheet: 55 °F to 125 °F outdoor (low-ambient kit needed below that).
Components & tests
Unlock all 4 components, specs, service mode and teardown
Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.
Get lifetime accessOfficial manufacturer documentation
Always confirm values against the tech sheet for the exact model.
OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Air-source heat pump outdoor unit beside a house in the snow by PeterEastern, CC BY-SA 4.0