Field manual · Dehumidifier

Hisense 35 / 50 / 70-pint dehumidifiers (DH-35K1SCLE to DH-70KP1SLE): quick sheet

Covers: Hisense portable dehumidifiers covered by one use and care guide: DH-35K1SCLE, DH-50K1SDLE, DH-70K1SLE, DH-50KD1SDLE and the pump models DH-50KP1SDLE and DH-70KP1SLE (KP = built-in pump), plus the similar DH50K1W, DH50KP1WG, DH70K1G and DH70KP1WG. No CPSC recall for Hisense-branded dehumidifiers was found (the big dehumidifier recalls were Gree, New Widetech and GD Midea units), but check the model against cpsc.gov.

Single sourceBrands: Hisense5 components

These are bucket dehumidifiers with an Empty Bucket interlock, a float switch, a hose port for gravity drain and, on KP models, a pump with a 16 ft hose. The guide does not define the error codes: it only says to call Hisense if a code appears. Treat the code meanings on third-party sites as unconfirmed. Most calls are pump-light faults from the hose, 'bucket full' with an empty bucket, icing in a cold basement, and no water collected.

Safety first

  • Plug into a grounded three-prong outlet; no extension cords.
  • Unplug before cleaning the filter, bucket or pump.
  • Sealed-system diagnosis or repair is blocked: refer to an EPA 608-certified technician.

How it works

The Empty Bucket light stops the unit when the bucket is full, missing or not seated. The float in the bucket has to be in place on its clip, or the unit reads full all the time.

Gravity drain: a garden hose on the hose port must run downhill to the floor drain with no kinks or loops.

Pump models push water up or sideways through the included 16 ft hose. The hose must be clicked into its quick-connect before you press Pump; a flashing pump light means the pump isn't working properly, most often from the hose.

In a cool room the coil frosts. Defrost turns the compressor off while the fan keeps running, so a silent compressor can be normal.

Once the humidity set point is reached, the compressor stops and the fan comes on now and then to sample the air. Continuous mode runs nonstop. Keep 12-18 in of clearance around the unit.

Components & tests

Unlock all 5 components, specs, service mode and teardown

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Clothes dryer with its vent duct in a small laundry closet by Introspectivedsgn, Pexels License

Diagnostic guides for this appliance

Other dehumidifiers manuals

Manual · Dehumidifier

Danby DDR dehumidifiers (incl. recalled Gree-built and New Widetech-built units): quick sheet

Danby portable dehumidifiers with the DDR model prefix (Danby, Danby Premiere, Danby Designer, plus the Danby-made Generations GDR and ArcticAire ADR lines). Two recall groups matter on every call: the Gree-built units recalled in 2013 (DDR3011, DDR30P, DDR4511, DDR45P, DDR6511, DDR65CHP, all date codes, sold January 2005 - August 2013) and the New Widetech-built units recalled in 2021 (made before September 1, 2017, sold February 2009 - August 2017, e.g. DDR45A3GDB, DDR70A3GDB, DDR60RGDD, DDR25E, DDR30E, DDR45E, DDR5009REE, DDR6009REE, DDR7009REE, DDR50A1GP, DDR60A2GP, DDR70A1GP, GDR5011BL). Current models (e.g. DDR020BJWDB through DDR050BJWDB, DDR060BECWDB) are later builds.

5 components6 common failuresDanby, Danby Premiere, Danby Designer
Manual · Dehumidifier

Santa Fe Ultra series / Ultra-Aire 70H and 120H whole-house ventilating dehumidifiers (Ultra70, Ultra120): quick sheet

Ducted whole-house ventilating dehumidifiers from Therma-Stor (Madison, WI): the Ultra-Aire 70H (now sold as the Santa Fe Ultra70) and Ultra-Aire 120H (now the Santa Fe Ultra120). 2024-on Santa Fe Ultra units use R-454B; the older Ultra-Aire 120H manual lists R-410A. Other Ultra-Aire models (120V, 98H) exist and have different numbers.

4 components4 common failuresSanta Fe, Ultra-Aire, Therma-Stor
Manual · Dehumidifier

Honeywell / Resideo TrueDRY DR65 and DR90 whole-house ventilating dehumidifiers: quick sheet

TrueDRY DR65 (DR65A1000, DR65A2000) and DR90 (DR90A1000, DR90A2000) ducted whole-house dehumidifiers sold through HVAC distributors, mostly 2010s installs. Discontinued; parts support varies. Figures below are from the A2000 spec data sheets unless noted.

4 components4 common failuresHoneywell Home / Resideo
Hisense 35 / 50 / 70-pint dehumidifiers (DH-35K1SCLE to DH-70KP1SLE): quick sheet · OnCall Tech