Field manual · Air Conditioner

Carrier Comfort 13 24ABB3 single-stage split air conditioner (Puron / R-410A): quick sheet

Covers: Carrier 24ABB3 Comfort-tier 13 SEER-class condensing units, 1.5 to 5 ton (sizes 18-60), in 208/230-1, 208/230-3, 460-3 and 575-3 versions. Model string per Carrier's product data: 24 (AC) + A (residential AC) + B (Comfort tier) + B (Puron major series) + 3 (13 SEER class) + capacity (18-60) + grille (A dense, W wide) + 0 + 0 + voltage digit (3 = 208/230-1, 5 = 208/230-3, 6 = 460-3, 1 = 575-3) + series digit, e.g. 24ABB336A003, 24ABB324A003, 24ABB360A003. Conventional 24 V control. Bryant and Payne sell sister value lines under their own model numbers; match the nameplate to the right literature. Search terms: 24ABB336A003, 24ABB348A003, Carrier Comfort 13, 24ABB3 capacitor.

Single sourceBrands: Carrier4 components

Entry-tier Carrier condenser with a scroll compressor, internal pressure relief and thermal overload, and a direct-drive propeller fan. No outdoor control board: diagnosis is the 24 V call, contactor, capacitor, fan and compressor. Carrier lists maximum SEER per size (with approved combinations) from 13.5 to 15.0.

Safety first

  • Lock out power; discharge capacitors.
  • Refrigerant work is blocked: EPA 608-certified technician.

How it works

Thermostat Y energizes the contactor; the contactor feeds the scroll compressor and fan motor.

Fan motor amps (FLA) are listed per size and voltage in the product data; compare measured amps to the nameplate.

Carrier lists long-line capability and low-ambient capability with a kit as standard features.

Components & tests

Unlock all 4 components, specs, service mode and teardown

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

Official manufacturer documentation

Always confirm values against the tech sheet for the exact model.

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): White retro-style refrigerator beside a kitchen sink cabinet by Pavel Danilyuk, Pexels License

Diagnostic guides for this appliance

Other air conditioners manuals

Manual · Air Conditioner

Carrier Infinity Greenspeed 24VNA6 air conditioner and 25VNA4 heat pump (variable speed): quick sheet

Carrier Infinity Greenspeed Intelligence variable-speed outdoor units: 24VNA6 air conditioner (up to 26 SEER) and 25VNA4 heat pump (up to 24 SEER, up to 13 HSPF), 2-5 ton. Nomenclature from the service manual: 24 = AC, 25 = HP; V = variable speed; N = Infinity series; A = Puron (R-410A); 6 / 4 = SEER tier; two digits = nominal capacity (e.g. 36 = 36,000 BTU/h); voltage digit 3 = 208/230-1; compressor ID 4 = variable-speed scroll, 5 = variable-speed rotary. Serial format: week + year + plant letter + sequence (e.g. 0118E00001). Other 24VNA families (24VNA0, 24VNA9) use different software and code lists.

5 components4 common failuresCarrier
Manual · Air Conditioner

Trane XV20i / XV18 variable-speed outdoor units (4TTV0 AC, 4TWV0 heat pump, ComfortLink II): quick sheet

Trane variable-speed TruComfort / ComfortLink II communicating outdoor units: 4TTV0 air conditioners (XV20i family, e.g. 4TTV0024A1000C, 4TTV0036, 4TTV0048, 4TTV0060, 4TTV0061) and 4TWV0 heat pumps (Service Facts 4T-V0-SF). They use an Integrated Variable Speed Control (IVSC) board and a Communicating Display Assembly (CDA) in the outdoor unit. Distributor listings note several 4TTV0 revisions; confirm the full model on the nameplate before ordering parts. Single-stage XR14/XR16 units are on a separate sheet.

4 components3 common failuresTrane
Manual · Air Conditioner

Lennox XC21 air conditioner and XP21 heat pump (Dave Lennox Signature, iComfort-enabled): quick sheet

Lennox XC21 (air conditioner, service literature Corp. 1007-L2) and XP21 (heat pump, Corp. 1031-L7), 2, 3, 4 and 5 ton, R-410A, expansion valve indoor coils only. Both use an A175 main control (outdoor control part number 101798-xx) that works in communicating (iComfort) or conventional 24 V mode, plus a separate fan motor control. The XP21 literature describes a two-stage scroll compressor; the 2018 XC21 literature describes the compressor as one-stage while the same control section covers two-stage units, so confirm staging on the nameplate. For ML14XC1/EL16XC1 single-stage units see the separate sheet.

4 components3 common failuresLennox