Bosch IDS 2.0 inverter ducted heat pump (BOVA-36HDN1-M20G / BOVA-60HDN1-M20G with BVA air handlers): quick sheet

Covers: Bosch Inverter Ducted Split (IDS) 2.0 outdoor heat pumps BOVA-36HDN1-M20G (2-3 ton) and BOVA-60HDN1-M20G (4-5 ton), up to 20.5 SEER (R-410A), matched with Bosch BVA-24/36/48/60WN1-M20 air handlers, BMAC coils or a gas furnace. Nomenclature: BOVA = outdoor unit; 36 / 60 = max nominal capacity (kBtu/h); H = heat pump; N1 = R-410A; M = 208/230 V 1 ph 60 Hz; 20 = SEER class; G = GMCC compressor. Earlier IDS (BOVA ... M18M, up to 18 SEER) and later IDS Light / IDS Premium units have their own manuals. Works with ordinary 24 V thermostats (no communicating control required).

Single sourceBrands: Bosch5 components

The outdoor unit runs a variable-speed (inverter) compressor and DC fan from a control board with a two-character LED display, LEDs and a point-check button that scrolls operating data (capacity, mode, compressor speed in Hz, sensor temperatures). Faults show as codes on that display; some codes are 'limited condition' status codes meaning the unit is protecting itself but still running.

Safety first

  • Up to about 380 VDC on the inverter: verify below 42 VDC before touching.
  • No charging or sealed-system steps: refer to an EPA 608 certified technician.

How it works

The unit reads Y1/Y2/O/W from the thermostat and varies compressor speed to match.

Sensors: T3 outdoor coil, T4 outdoor ambient, T5 compressor discharge, Tf module/heat sink, Th suction (as listed in Bosch's code table) plus a pressure transducer (PT) and a high pressure switch.

Point check: pressing the check button steps through numbered data points, e.g. 0 = capacity (H3 = 3 ton heat pump), 1 = mode (0 standby, 2 cooling, 3 heating), 2 = compressor speed in Hz.

The inverter bus can hold about 380 VDC; Bosch says to wait and verify less than 42 VDC at the inverter test points P-N before service.

Components & tests

Unlock all 5 components, specs, service mode and teardown

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

Official manufacturer documentation

Always confirm values against the tech sheet for the exact model.

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work. © 2026 OnCall Tech. Original content; not a reproduction of any manufacturer document.Generic part photos (not of this brand): Air-source heat pump outdoor unit beside a house in the snow by PeterEastern, CC BY-SA 4.0

Diagnostic guides for this appliance

Other air conditioners manuals

Manual · Air Conditioner

Carrier Infinity Greenspeed 24VNA6 air conditioner and 25VNA4 heat pump (variable speed): quick sheet

Carrier Infinity Greenspeed Intelligence variable-speed outdoor units: 24VNA6 air conditioner (up to 26 SEER) and 25VNA4 heat pump (up to 24 SEER, up to 13 HSPF), 2-5 ton. Nomenclature from the service manual: 24 = AC, 25 = HP; V = variable speed; N = Infinity series; A = Puron (R-410A); 6 / 4 = SEER tier; two digits = nominal capacity (e.g. 36 = 36,000 BTU/h); voltage digit 3 = 208/230-1; compressor ID 4 = variable-speed scroll, 5 = variable-speed rotary. Serial format: week + year + plant letter + sequence (e.g. 0118E00001). Other 24VNA families (24VNA0, 24VNA9) use different software and code lists.

5 components4 common failuresCarrier
Manual · Air Conditioner

Trane XV20i / XV18 variable-speed outdoor units (4TTV0 AC, 4TWV0 heat pump, ComfortLink II): quick sheet

Trane variable-speed TruComfort / ComfortLink II communicating outdoor units: 4TTV0 air conditioners (XV20i family, e.g. 4TTV0024A1000C, 4TTV0036, 4TTV0048, 4TTV0060, 4TTV0061) and 4TWV0 heat pumps (Service Facts 4T-V0-SF). They use an Integrated Variable Speed Control (IVSC) board and a Communicating Display Assembly (CDA) in the outdoor unit. Distributor listings note several 4TTV0 revisions; confirm the full model on the nameplate before ordering parts. Single-stage XR14/XR16 units are on a separate sheet.

4 components3 common failuresTrane
Manual · Air Conditioner

Lennox XC21 air conditioner and XP21 heat pump (Dave Lennox Signature, iComfort-enabled): quick sheet

Lennox XC21 (air conditioner, service literature Corp. 1007-L2) and XP21 (heat pump, Corp. 1031-L7), 2, 3, 4 and 5 ton, R-410A, expansion valve indoor coils only. Both use an A175 main control (outdoor control part number 101798-xx) that works in communicating (iComfort) or conventional 24 V mode, plus a separate fan motor control. The XP21 literature describes a two-stage scroll compressor; the 2018 XC21 literature describes the compressor as one-stage while the same control section covers two-stage units, so confirm staging on the nameplate. For ML14XC1/EL16XC1 single-stage units see the separate sheet.

4 components3 common failuresLennox
Bosch IDS 2.0 inverter ducted heat pump (BOVA-36HDN1-M20G / BOVA-60HDN1-M20G with BVA air handlers): quick sheet · OnCall Tech