Furnace inducer (draft) motor not starting
Work from mechanical to electrical: does the wheel turn freely, is 120 V reaching the motor, and is the board sending it. A seized motor is replaced as an assembly; no output from the board points to the board relay or a safety input.
Before you start
- Turn off power at the furnace switch and breaker before handling the inducer; live tests only with insulated probes.
- Discharge any inducer capacitor before testing.
- Do not disturb the vent connection beyond reconnecting it; vent repairs go to a licensed installer.