Field pattern: washer-dryer combo 'runs water during dry' or won't dry with the water off (condensing uses cold water by design)

Many condensing combos spray cold tap water to cool the drying air and pull moisture out, then pump it away. Water flow during dry is normal, and with the supply off the clothes will not dry. The wrong turn is replacing the inlet valve as 'leaking' or treating a combo with a shut-off water supply as a heater failure.

Cross-checked ~30 min easyBrands: LG, GE, Whirlpool, All-in-one combos

Before you start

  • Unplug before opening panels
  • Many combos need a 240 V supply: voltage checks are caution

Diagnostic steps

Unlock all 6 steps with expected values

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work.