Hoshizaki
1 field manuals · 9 error codes · 3 guides
Hoshizaki ice makers
All ice makers →Error codes
Undercounter ice maker not making ice
Check power, water supply and pressure, drain (pump models stop when they cannot drain), bin sensor, cleaning status, condenser and room temperature. Scale is the most common cause on older machines.
7 steps ~60 minmoderate
Commercial cuber long freeze or long harvest alarm
Long freeze usually means poor heat rejection or water problems; long harvest usually means scale or harvest components. Do the safe checks; refrigeration work goes to an EPA 608-certified tech.
6 steps ~60 minmoderate
Nugget/flake machine auger overload or no ice sensed
Scale on the evaporator and auger is the most common cause of auger overload. Low water starves the freezing cylinder. Descale and check water before replacing gear motors.
5 steps ~90 minmoderate