Fujitsu
Fujitsu General
1 field manuals · 17 error codes · 3 guides
Fujitsu air conditioners
All air conditioners →Error codes
11 (Operation 1 / Timer 1 blinks) Serial communication error12 Wired remote communication error23 Indoor/outdoor combination error32 Indoor PCB memory error41 Indoor room thermistor fault42 Indoor coil thermistor error51 Indoor fan motor fault53 Drain error62 Outdoor main PCB memory error63 Inverter error71 Discharge thermistor error73 Outdoor coil thermistor error74 Outdoor ambient thermistor error94 Compressor overcurrent (trip det…97 Outdoor fan motor error99 Four-way valve errorA1 Discharge temperature too high
Mini-split indoor unit blinking light (reading the code)
A blinking pattern is a fault code. Count the blinks before you reset power, because a breaker reset erases the code. Then look it up for the brand and fix the cause.
4 steps ~30 minmoderate
Mini-split communication error: interconnect wiring check
Most communication faults are wiring: swapped terminals, loose screws, splices or damaged cable, often after a new install or a storm. Check power, then terminations at both ends, then the data signal, before replacing a board.
5 steps ~60 minadvanced
Identify a Fujitsu
Reading the model number
Not sourced.
Manufacture date from the serial number
Single sourceNo known date code in the serial; get the build date from Fujitsu service or its warranty lookup.
Single source.