Motor or compressor reads open when hot: internal thermal protector tripped, not (yet) a dead winding
Many small motors and hermetic compressors have a thermal protector built into the windings that opens when the motor overheats and closes again on its own when it cools. Measured hot, the motor can look like it has an open winding. Before condemning it, let it cool fully and retest. If it then runs, the real job is to find why it overheated: low voltage, a failed capacitor, a seized bearing or blocked pump, or poor airflow over a condenser. Compressor sealed-system causes go to an EPA 608 technician.
Before you start
- Unplug or lock out before measuring resistance; discharge any capacitor first
- Hot compressor shells and motor housings can burn; let them cool
- Never bypass or jump out a thermal protector
- Sealed-system diagnosis (charge, restriction, pressures) is blocked: refer to an EPA 608 technician
Diagnostic steps
Unlock all 5 steps with expected values
Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.
Get lifetime accessOnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work.