Well pressure tank annual check: precharge, switch settings and cycle time
A bladder or diaphragm well tank holds an air charge that should sit about 2 psi below the pressure switch cut-in (for example 28 psi on a 30/50 switch, 38 psi on a 40/60). The charge can only be read with the pump off and the system drained to zero water pressure. A yearly check catches a slowly leaking charge before it short-cycles the pump. Water from the air valve means a failed bladder.
Before you start
- Turn off the well pump breaker before draining; a pump running against an empty tank can be damaged and the pressure switch terminals are 240 V on many systems
- Do not adjust the pressure switch with the cover off and power on
Diagnostic steps
Unlock all 6 steps with expected values
Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.
Get lifetime accessOnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work.
