Known issue: ductless heat pump outdoor fan motors overheating (Carrier/Bryant 2019, Lennox 2020 recalls)
Two CPSC recalls cover overheating ductless outdoor units. October 2019: about 5,350 Carrier and Bryant multi- and single-zone units (Carrier 38MGQC18, 38MGQF48, 38MBQB48; Bryant 538TEQ018RCMA, 538TEQ048RFMA, 538REQ048RBMA; sold March 2015 to April 2019), fan motor failure, free repair. February 2020: about 1,650 Lennox units (MPA018S4M-1P, MPA048S4S-1P, MPA048S4M-1P, serials beginning 6915 or 6916; sold January 2016 to November 2019), free replacement of the outdoor unit. Both told owners to keep flammables 24 inches away until fixed.
Before you start
- Kill power at the disconnect before touching the outdoor unit; inverter boards hold a charge, wait for the LED to go out
- Refrigerant circuit work is EPA 608: refer
- Keep foliage and anything flammable 24 inches away from a recalled unit
Diagnostic steps