Field pattern: range hood 'weak suction, needs a new motor' (filters, damper, duct and cap first)
Weak capture on a hood whose fan runs is usually airflow restriction: loaded filters, a damper that does not open (shipping tape on new units), an undersized or long duct, a crushed flex section or a blocked exterior cap. Cosmo's tissue test with the duct on and off separates the hood from the installation in minutes.
Before you start
- Unplug or switch off the hood before removing the chimney, duct or filters
- Support the hood when disconnecting the duct