Central AC keeps running after the thermostat is satisfied or turned off

Separate two complaints first: a system that runs very long cycles on a hot day but still cycles off is usually a capacity, airflow or load problem; a condenser that never stops, even with the thermostat off, is usually an electrical fault. The classic electrical cause is a contactor whose contacts have welded closed, followed by a shorted thermostat cable that keeps 24 V on the Y circuit. Isolate which one it is before replacing anything.

Single source ~40 min moderateBrands: All

Before you start

  • The outdoor unit has line voltage (typically 240 V) even when the contactor is open; pull the outdoor disconnect and verify dead before touching the contactor or capacitor
  • Discharge the run capacitor before working near it
  • No refrigerant work: if the cause turns out to be low charge or a sealed-system issue, refer to an EPA 608 certified technician

Diagnostic steps

Unlock all 5 steps with expected values

Full library + AI assistant + the OnCall Tech app for iPhone & Android. $34.90, one time.

Get lifetime access

OnCall Tech is a reference tool for trained technicians and can make mistakes. Always disconnect power and confirm with the manufacturer's documentation before you work.