Grundfos
2 field manuals · 0 error codes · 2 guides
Grundfos sump & well pumps
All sump & well pumps →Well pump hums, won't start or trips overload: control box test (3-wire)
On a 3-wire submersible, the start capacitor and relay in the control box are the most common surface failures and can be tested with a meter. First confirm power through the pressure switch, then test the box. If the box is good or the system is 2-wire, the problem is down the well and goes to a well contractor.
8 steps ~60 minadvanced
Constant-pressure well drive shows a fault or pressure surges
Read the code first; it tells you whether the problem is supply power, settings, the transducer or the pump/motor. Surging at low flow is almost always tank precharge. Use the drive maker's code list; the examples here are Franklin SubDrive/MonoDrive Connect.
7 steps ~60 minadvanced